Current through Register Vol. 51, No. 25, December 13, 2024
Section 10.53.09.03 - Cleansing Procedures Prior to sterilization as required in Regulation .03 of this chapter, tweezers and needle caps shall be:
A. Mechanically precleaned as follows: (a) Cleansed with a clean cotton ball or swab moistened with a low-residue detergent and cool water;(b) Accumulated in a holding container by submersion in a low-residue detergent and cool water; and(c) Then, thoroughly rinsed with warm water and drained;B. Then, cleaned by soaking in a protein-dissolving detergent enzyme cleaner or in an ultrasound cleaning unit according to manufacturer's instructions; andMd. Code Regs. 10.53.09.03
Regulations .03 adopted under new chapter, Sterilization Procedures, effective June 20, 2005 (32:12 Md. R. 1047); amended and recodified from .02 effective 51:15 Md. R. 710, eff. 8/5/2024.