Section 10.53.09.03 - Cleansing Procedures Prior to sterilization as required in Regulation .03 of this chapter, tweezers and needle caps shall be:
A. Mechanically precleaned as follows: (a) Cleansed with a clean cotton ball or swab moistened with a low-residue detergent and cool water;(b) Accumulated in a holding container by submersion in a low-residue detergent and cool water; and(c) Then, thoroughly rinsed with warm water and drained;B. Then, cleaned by soaking in a protein-dissolving detergent enzyme cleaner or in an ultrasound cleaning unit according to manufacturer's instructions; andMd. Code Regs. 10.53.09.03