Section 09.12.66.19 - Electrical RequirementsA. Electrical systems, conductors, and equipment installed on or used in conjunction with inflatable amusement attractions shall conform to the requirements of the National Electrical Code, ANSI/NFPA #70-2005.B. Each owner shall ensure that electrical systems required to operate the inflatable amusement attractions are maintained by a qualified person.C. Wiring Methods.(1) Flexible cords used with temporary and portable lights and extension cord sets used in conjunction with inflatable amusement attractions shall be:(a) Suitable for location (physical damage);(b) Suitable for use (outdoor);(c) Suitable for voltage (insulation rating); and(d) Adequate for ampacity (conductor size).(2) Flexible cords and extension cord sets shall be continuous without splice or tap between connectors.D. Lighting systems. Lighting systems, including fluorescent lighting systems, shall be: (2) Protected against accidental contact and breakage; and(3) Capable of containing the pieces of a broken light should breakage occur.Md. Code Regs. 09.12.66.19