La. Admin. Code tit. 51 § XXIV-513

Current through Register Vol. 50, No. 3, March 20, 2024
Section XXIV-513 - Suction Outlet [formerly paragraph 24:013-9]
A. If the suction outlet system, such as a filtration system, booster system, automatic cleaning system, solar system, etc., has a single suction outlet, or multiple suction outlets which can be isolated by valves, each suction outlet shall protect against user entrapment by either:
1. an antivortex cover;
2. a 12 inch by 12 inch grate or larger;
3.Section 511. C. Main Drain;
4. other means approved by the state health officer.

La. Admin. Code tit. 51, § XXIV-513

Promulgated by the Department of Health and Hospitals, Office of Public Health, LR 28:1441 (June 2002).
AUTHORITY NOTE: Promulgated in accordance with the provisions of R.S. 40:4(A)(11) and R.S. 40:5(3)(16)(17)(20).