Table 305.B-School/Classroom Lighting | ||||||
Room Type Classification | Direct Lighting Footcandle Levels (1) | Indirect Footcandle Levels (2) | ||||
Maximum | Average | Minimum | Maximum | Average | Minimum | |
Administrative Areas | ||||||
Offices/Receptionist | 75 | 50 | 25 | 60 | 40 | 20 |
Storage Rooms | 38 | 25 | 13 | 38 | 25 | 13 |
Restrooms | 38 | 25 | 13 | 38 | 25 | 13 |
Conference/Resource Rooms | 75 | 50 | 25 | 60 | 40 | 20 |
Healthcare Area | 75 | 50 | 25 | 60 | 40 | 20 |
Teacher Prep/Work Area | 75 | 50 | 25 | 60 | 40 | 20 |
Classrooms | ||||||
General Classrooms | 75 | 50 | 25 | 60 | 40 | 20 |
Visual Arts Rooms | 75 | 50 | 25 | 60 | 40 | 20 |
Modular Technology Labs | 75 | 50 | 25 | 60 | 40 | 20 |
Computer Aided/Drafting Labs | 45 | 30 | 15 | 45 | 30 | 15 |
Industrial Arts Rooms | 90 | 60 | 30 | 90 | 60 | 30 |
Computer Labs | 60 | 40 | 20 | 60 | 40 | 20 |
Graphics Labs | 75 | 50 | 25 | 60 | 40 | 20 |
Life Skills Labs | 75 | 50 | 25 | 75 | 50 | 25 |
Science Rooms/Labs | 75 | 50 | 25 | 75 | 50 | 25 |
Laundry Rooms | 38 | 25 | 13 | 38 | 25 | 13 |
Music Rooms | 75 | 50 | 25 | 60 | 40 | 20 |
Large Group Instruction Rooms | 75 | 50 | 25 | 60 | 40 | 20 |
Media Center | ||||||
Active Areas | 75 | 50 | 25 | 60 | 40 | 20 |
Inactive Areas | 60 | 40 | 20 | 60 | 40 | 20 |
Student Dining/Auditoriums | ||||||
Assembly | 30 | 20 | 10 | N/A | ||
Stage/Work Lights | 30 | 20 | 10 | N/A | ||
Makeup/Dressing Rooms | 75 | 50 | 25 | 75 | 50 | 25 |
Theatrical Control Room | 45 | 30 | 15 | 45 | 30 | 15 |
Kitchen | 60 | 40 | 20 | N/A | ||
Dining Areas | 60 | 40 | 20 | 60 | 40 | 20 |
Athletic Areas | ||||||
Gymnasium-Elementary School | 75 | 50 | 25 | N/A | ||
Gymnasium-Middle School | 75 | 50 | 25 | N/A | ||
Gymnasium-High School | 90 | 60 | 30 | N/A | ||
Multi-use Physical Education Rooms | 75 | 50 | 25 | N/A | ||
Locker Rooms | 38 | 25 | 13 | 38 | 25 | 13 |
Circulation | ||||||
Hallways | 30 | 20 | 10 | 30 | 20 | 10 |
Stairwells | 30 | 20 | 10 | 30 | 20 | 10 |
Maintenance Areas | ||||||
Custodial Closets | 45 | 30 | 15 | 45 | 30 | 15 |
Mechanical Rooms | 45 | 30 | 15 | 45 | 30 | 15 |
Footnotes to Table 305.B
(1) Direct lighting refers to light that is being directed in a downward direction towards the surface being illuminated.
(2) Indirect lighting refers to light that is directed at least partially in an upward direction or is reflected in some manner towards the surface being illuminated.
La. Admin. Code tit. 51, § XVII-305