Current through Register Vol. 50, No. 11, November 20, 2024
Section I-9913 - Nurse/Care Team Work AreasA. Each floor and/or household of a nursing facility shall have a nurse/care team work area in locations that are suitable to perform necessary functions. These nurse/care team work areas may be in centralized or decentralized locations, as long as the locations are suitable to perform necessary functions. 1. Each centralized nurse/care team area shall be equipped with working space and accommodations for recording and charting purposes by nursing facility staff with secured storage space for in-house resident records. a. Exception. Accommodations for recording and charting are not required at the central work area where decentralized work areas are provided.2. Each decentralized work area, where provided, shall contain working space and accommodations for recording and charting purposes with storage space for administrative activities and in-house resident records.3. The nurse/care team work areas shall be equipped to receive resident calls through a communication system from resident rooms, toileting and bathing facilities. a. In the case of an existing centralized nurse/care team work area, this communication may be through audible or visible signals and may include wireless systems.b. In those facilities that have moved to decentralized nurse/care team work areas, the facility may utilize other electronic systems that provide direct communication from the resident to the staff.B. There shall be a medicine preparation room or area. Such room or area shall contain a work counter, preparation sink, refrigerator, task lighting and lockable storage for controlled drugs.C. There shall be a clean utility room on each floor designed for proper storage of nursing equipment and supplies. Such room shall contain task lighting and storage for clean and sterile supplies.D. There shall be a separate soiled utility room designed for proper cleansing, disinfecting and sterilizing of equipment and supplies. At a minimum, it shall contain a clinical sink or equivalent flushing-rim sink with a rinsing hose or bed pan sanitizer, hand washing facilities, soiled linen receptacles and waste receptacle. Each floor of a nursing facility shall have a soiled utility room.La. Admin. Code tit. 48, § I-9913
Promulgated by the Department of Health and Hospitals, Office of the Secretary, Bureau of Health Services Financing, LR 24:64 (January 1998), Promulgated by the Department of Health, Bureau of Health Services Financing, LR 421926 11/1/2016).AUTHORITY NOTE: Promulgated in accordance with R.S. 40:2009.1-2116.