La. Admin. Code tit. 43 § XIII-909

Current through Register Vol. 50, No. 9, September 20, 2024
Section XIII-909 - Nominal Wall Thickness (t) for Steel Pipe [49 CFR 192.109]
A. If the nominal wall thickness for steel pipe is not known, it is determined by measuring the thickness of each piece of pipe at quarter points on one end. [ 49 CFR 192.109(a)]
B. However, if the pipe is of uniform grade, size, and thickness and there are more than 10 lengths, only 10 percent of the individual lengths, but not less than 10 lengths, need be measured. The thickness of the lengths that are not measured must be verified by applying a gauge set to the minimum thickness found by the measurement. The nominal wall thickness to be used in the design formula in §905 is the next wall thickness found in commercial specifications that is below the average of all the measurements taken. However, the nominal wall thickness used may not be more than 1.14 times the smallest measurement taken on pipe less than 20 inches (508 millimeters) in outside diameter, nor more than 1.11 times the smallest measurement taken on pipe 20 inches (508 millimeters) or more in outside diameter. [ 49 CFR 192.109(b)]

La. Admin. Code tit. 43, § XIII-909

Promulgated by the Department of Natural Resources, Office of Conservation, LR 9:221 (April 1983), amended LR 10:513 (July 1984), LR 27:1537 (September 2001), LR 30:1230 (June 2004).
AUTHORITY NOTE: Promulgated in accordance with R.S. 30:501 et seq.