La. Admin. Code tit. 43 § XIII-1923

Current through Register Vol. 50, No. 9, September 20, 2024
Section XIII-1923 - Service Lines: Cast Iron and Ductile Iron [49 CFR 192.373]
A. Cast or ductile iron pipe less than 6 inches (152 millimeters) in diameter may not be installed for service lines. [ 49 CFR 192.373(a)]
B. If cast iron pipe or ductile iron pipe is installed for use as a service line, the part of the service line which extends through the building wall must be of steel pipe. [ 49 CFR 192.373(b)]
C. A cast iron or ductile iron service line may not be installed in unstable soil or under a building. [ 49 CFR 192.373(c)]

La. Admin. Code tit. 43, § XIII-1923

Promulgated by the Department of Natural Resources, Office of Conservation, LR 9:234 (April 1983), amended LR 10:527 (July 1984), LR 27:1543 (September 2001), LR 30:1250 (June 2004).