Section XIII-1907 - Customer Meters and Regulators: Installation [49 CFR 192.357]
A. Each meter and each regulator must be installed so as to minimize anticipated stresses upon the connecting piping and the meter. [ 49 CFR 192.357(a)]
B. When close all-thread nipples are used, the wall thickness remaining after the threads are cut must meet the minimum wall thickness requirements of this Subpart. [ 49 CFR 192.357(b)]
C. Connections made of lead or other easily damaged material may not be used in the installation of meters or regulators. [ 49 CFR 192.357(c)]
D. Each regulator that might release gas in its operation must be vented to the outside atmosphere. [ 49 CFR 192.357(d)]

La. Admin. Code tit. 43, § XIII-1907

Promulgated by the Department of Natural Resources, Office of Conservation, LR 9:234 (April 1983), amended LR 10:526 (July 1984), LR 30:1248 (June 2004).