Section XIII-1105 - Valves [49 CFR 192.145]A. Except for cast iron and plastic valves, each valve must meet the minimum requirements of ANSI/API Spec 6D (incorporated by reference, see §507), or to a national or international standard that provides an equivalent performance level. A valve may not be used under operating conditions that exceed the applicable pressure-temperature ratings contained in those requirements [ 49 CFR 192.145(a)].B. Each cast iron and plastic valve must comply with the following. [ 49 CFR 192.145(b)] 1. The valve must have a maximum service pressure rating for temperatures that equal or exceed the maximum service temperature. [ 49 CFR 192.145(b)(1)]2. The valve must be tested as part of the manufacturing, as follows. [ 49 CFR 192.145(b)(2)] a. With the valve in the fully open position, the shell must be tested with no leakage to a pressure at least 1.5 times the maximum service rating. [ 49 CFR 192.145(b)(2)(i)]b. After the shell test, the seat must be tested to a pressure no less than 1.5 times the maximum service pressure rating. Except for swing check valves, test pressure during the seat test must be applied successively on each side of the closed valve with the opposite side open. No visible leakage is permitted. [ 49 CFR 192.145(b)(2)(ii)]c. After the last pressure test is completed, the valve must be operated through its full travel to demonstrate freedom from interference. [ 49 CFR 192.145(b)(2)(iii)]C. Each valve must be able to meet the anticipated operating conditions. [ 49 CFR 192.145(c)]D. No valve having shell (body, bonnet, cover, and/or end flange) components made of ductile iron may be used at pressures exceeding 80 percent of the pressure ratings for comparable steel valves at their listed temperature. However, a valve having shell components made of ductile iron may be used at pressures up to 80 percent of the pressure ratings for comparable steel valves at their listed temperature, if: [ 49 CFR 192.145(d)] 1. the temperature-adjusted service pressure does not exceed 1,000 psi (7 MPa) gauge; and [ 49 CFR 192.145(d)(1)]2. welding is not used on any ductile iron component in the fabrication of the valve shells or their assembly. [ 49 CFR 192.145(d)(2)]E. No valve having shell (body, bonnet, cover, and/or end flange) components made of cast iron, malleable iron, or ductile iron may be used in the gas pipe components of compressor stations. [49 CFR 192.145(e)]F. Except for excess flow valves, plastic valves installed after January 22, 2019, must meet the minimum requirements of a listed specification. A valve may not be used under operating conditions that exceed the applicable pressure and temperature ratings contained in the listed specification. [49 CFR 192.145(f)]La. Admin. Code tit. 43, § XIII-1105
Promulgated by the Department of Natural Resources, Office of Conservation, LR 9:223 (April 1983), amended LR 10:515 (July 1984), LR 18:855 (August 1992), LR 27:1539 (September 2001), LR 30:1232 (June 2004), LR 31:682 (March 2005), LR 33:479 (March 2007), LR 38:115 (January 2012), Amended LR 441037 (6/1/2018), Amended LR 461584 (11/1/2020).AUTHORITY NOTE: Promulgated in accordance with R.S. 30:501 et seq.