La. Admin. Code tit. 33 § XV-1729

Current through Register Vol. 50, No. 9, September 20, 2024
Section XV-1729 - Power Failures
A. If electrical power at a panoramic irradiator is lost for longer than ten seconds, the sources shall automatically return to the shielded position.
B. The lock on the door of the radiation room of a panoramic irradiator shall remain locked in the event of a power failure.
C. During a power failure, the area of any irradiator where sources are located shall be entered only when using an operable and calibrated radiation survey meter.

La. Admin. Code tit. 33, § XV-1729

Promulgated by the Department of Environmental Quality, Office of Air Quality and Radiation Protection, Radiation Protection Division, LR 24:2116 (November 1998).
AUTHORITY NOTE: Promulgated in accordance with R.S. 30:2001 et seq.