La. Admin. Code tit. 33 § V-4357

Current through Register Vol. 50, No. 6, June 20, 2024
Section V-4357 - Operating Record
A. The owner or operator must keep a written operating record at his facility.
B. Records of each hazardous waste received, treated, stored, or disposed of at the facility must be recorded, as they become available, and maintained in the operating record for three years, unless otherwise specified in Paragraphs B.1-17 of this Section. These records shall include the following information:
1. a description and the quantity of each hazardous waste received, and the method(s) and date(s) of its treatment, storage, or disposal at the facility as required by LAC 33:V.4999.Appendix F. This information must be maintained in the operating record until closure of the facility;
2. the location of each hazardous waste within the facility and the quantity at each location. For disposal facilities, the location and quantity of each hazardous waste must be recorded on a map or diagram of each cell or disposal area. For all facilities, this information must include cross-references to manifest document numbers, if the waste was accompanied by a manifest. This information must be maintained in the operating record until closure of the facility;
3. the estimated or manifest-reported weight, or volume and density, where applicable, in one of the units of measure specified in Table 1 of this Section:

Table 1. Units for Reporting

Unit of Measure

Code1

Gallons

G

Gallons per Hour

E

Gallons per Day

U

Liters

L

Liters per Hour

H

Liters per Day

V

Short Tons per Hour

D

Metric Tons per Hour

W

Short Tons per Day

N

Metric Tons per Day

S

Pounds per Hour

J

Kilograms per Hour

R

Cubic Yards

Y

Cubic Meters

C

Acres

B

Acre-feet

A

Hectares

Q

Hectare-meter

F

British thermal units per Hour

I

Pounds

P

Short tons

T

Kilograms

K

Tons

M

1 Single digit symbols are used here for data processing purposes.

4. the method(s) (by handling code(s) as specified in Table 2 of this Section) and date(s) of treatment, storage, or disposal:

Table 2. Handling Codes for Treatment, Storage, and Disposal Methods

Enter the handling code(s) listed below that most closely represents the technique(s) used at the facility to treat, store, or dispose of each quantity of hazardous waste received.

Storage

S01 Container (barrel, drum, etc.)

S02 Tank

S03 Waste Pile

S04 Surface Impoundment

S05 Drip Pad

S06 Containment Building (Storage)

S99 Other Storage (specify)

Treatment

Thermal Treatment

T06 Liquid injection incinerator

T07 Rotary kiln incinerator

T08 Fluidized bed incinerator

T09 Multiple hearth incinerator

T10 Infrared furnace incinerator

T11 Molten salt destructor

T12 Pyrolysis

T13 Wet air oxidation

T14 Calcination

T15 Microwave discharge

T18 Other (specify)

Chemical Treatment

T19 Absorption mound

T20 Absorption field

T21 Chemical fixation

T22 Chemical oxidation

T23 Chemical precipitation

T24 Chemical reduction

T25 Chlorination

T26 Chlorinolysis

T27 Cyanide destruction

T28 Degradation

T29 Detoxification

T30 Ion exchange

T31 Neutralization

T32 Ozonation

T33 Photolysis

T34 Other (specify)

Physical Treatment

Separation of Components

T35 Centrifugation

T36 Clarification

T37 Coagulation

T38 Decanting

T39 Encapsulation

T40 Filtration

T41 Flocculation

T42 Flotation

T43 Foaming

T44 Sedimentation

T45 Thickening

T46 Ultrafiltration

T47 Other (specify)

Removal of Specific Components

T48 Absorption-molecular sieve

T49 Activated carbon

T50 Blending

T51 Catalysis

T52 Crystallization

T53 Dialysis

T54 Distillation

T55 Electrodialysis

T56 Electrolysis

T57 Evaporation

T58 High gradient magnetic separation

T59 Leaching

T60 Liquid ion exchange

T61 Liquid-liquid extraction

T62 Reverse osmosis

T63 Solvent recovery

T64 Stripping

T65 Sand filter

T66 Other (specify)

Biological Treatment

T67 Activated sludge

T68 Aerobic lagoon

T69 Aerobic tank

T70 Anaerobic tank

T71 Composting

T72 Septic tank

T73 Spray irrigation

T74 Thickening filter

T75 Trickling filter

T76 Waste stabilization pond

T77 Other (specify)

T78 [Reserved]

T79 [Reserved]

Boilers and Industrial Furnaces

T80 Boiler

T81 Cement Kiln

T82 Lime Kiln

T83 Aggregate Kiln

T84 Phosphate Kiln

T85 Coke Oven

T86 Blast Furnace

T87 Smelting, Melting, or Refining Furnace

T88 Titanium Dioxide Chloride Process Oxidation Reactor

T89 Methane Reforming Furnace

T90 Pulping Liquor Recovery Furnace

T91 Combustion Device Used in the Recovery of Sulfur Values from Spent Sulfuric Acid

T92 Halogen Acid Furnaces

T93 Other Industrial Furnaces Listed in LAC 33:V.109 (specify)

Other Treatment

T94 Containment Building (Treatment)

Disposal

D79 Underground Injection

D80 Landfill

D81 Land Treatment

D82 Ocean Disposal

D83 Surface Impoundment (to be closed as a landfill)

D99 Other Disposal (specify)

Miscellaneous

X01 Open Burning/Open Detonation

X02 Mechanical Processing

X03 Thermal Unit

X04 Geologic Repository

X99 Other (specify)

5. records and results of waste analyses and trial tests performed as specified in LAC 33:V.2237.A, 2245, 4313, 4445, 4453, 4467, 4481, 4507, 4515, 4527, 4539, 4557, and 4727;
6. summary reports and details of all incidents that require implementing the contingency plan as specified in LAC 33:V.1513.F.9;
7. records and results of inspections as required by LAC 33:V.1509.D (except these data need be kept only three years);
8. monitoring, testing, or analytical data, and corrective action where required by LAC 33:V.4320, 4367, 4375, 4433, 4437, 4440, 4449, 4451, 4455, 4470, 4472, 4474, 4483, 4485, 4489.D.1, 4497, 4498, 4499, 4501, 4502, 4519, 4529, 4557, 4559, 4587, 4589, 4725, 4727, 4729, 4731, 4733, 4735, 4737, and 4739. Maintain this information in the operating record for three years, except for records and results pertaining to groundwater monitoring and cleanup, and response action plans for surface impoundments, waste piles, and landfills, which must be maintained in the operating record until closure of the facility;

[COMMENT: As required by LAC 33:V.4375, monitoring data at disposal facilities must be kept throughout the post-closure period.]

9. all closure cost estimates under LAC 33:V.4401 and, for disposal facilities, all post-closure cost estimates under LAC 33:V.4405. This information must be maintained in the operating record until closure of the facility;
10. records of the quantities (and date of placement) for each shipment of hazardous waste placed in land disposal units under an extension to the effective date of any land disposal prohibition granted in accordance with LAC 33:V.2239, monitoring data required in accordance with an exemption under LAC 33:V.2241 or 2271 or the applicable notice required of a generator under LAC 33:V.2245. All of this information must be maintained in the operating record until closure of the facility;
11. for an off-site treatment facility, a copy of the notice and the certification and demonstration, if applicable, required of the generator or the owner or operator under LAC 33:V.2245 or 2247;
12. for an on-site treatment facility, the information contained in the notice (except the manifest number) and the certification and demonstration, if applicable, required by the generator or the owner or operator under LAC 33:V.2245 or 2247;
13. for an off-site land disposal facility, a copy of the notice and the certification and demonstration, if applicable, required by the generator or the owner or operator of a treatment facility under LAC 33:V.2245 or 2247;
14. for an on-site land disposal facility, the information contained in the notice (except the manifest number) and the certification and demonstration, if applicable, required by the generator or the owner or operator of a treatment facility under LAC 33:V.2245 or 2247;
15. for an off-site storage facility, a copy of the notice and the certification and demonstration, if applicable, required by the generator or the owner or operator under LAC 33:V.2245 or 2247;
16. for an on-site storage facility, the information contained in the notice (except the manifest number) and the certification and demonstration, if applicable, required by the generator or the owner or operator of a treatment facility under LAC 33:V.2245 or 2247;
17. monitoring, testing, or analytical data and corrective action data where required by LAC 33:V.4367, 4373.F, and 4373.I, and the certification as required by LAC 33:V.4441.F. This information must be maintained in the operating record until closure of the facility.

La. Admin. Code tit. 33, § V-4357

Promulgated by the Department of Environmental Quality, Office of Solid and Hazardous Waste, Hazardous Waste Division, LR 10:200 (March 1984), amended LR 10:496 (July 1984), LR 15:378 (May 1989), LR 16:220 (March 1990), LR 17:658 (July 1991), LR 18:723 (July 1992), LR 20:1000 (September 1994), LR 21:266 (March 1995), LR 22:837 (September 1996), amended by the Office of Waste Services, Hazardous Waste Division, LR 24:1744 (September 1998), LR 25:484 (March 1999), amended by the Office of Environmental Assessment, Environmental Planning Division, LR 25:1803 (October 1999), amended by the Office of the Secretary, Legal Affairs Division, LR 33:1626 (August 2007), LR 34:633 (April 2008), LR 34:1018 (June 2008), LR 34:1899 (September 2008).
AUTHORITY NOTE: Promulgated in accordance with R.S. 30:2180 et seq.