La. Admin. Code tit. 33 § V-1527

Current through Register Vol. 50, No. 6, June 20, 2024
Section V-1527 - Receiving and Monitoring Incoming Waste
A. Each site which treats, stores, or disposes of hazardous wastes generated off site shall be equipped to accomplish the following:
1. provide control of all incoming waste to prevent entry of unrecorded and unanalyzed hazardous waste; and
2. measure quantity and type by taking and analyzing a representative sample of waste received to verify the information on the manifest, and to determine proper method for handling and disposal.
B. Each facility within the site which receives hazardous wastes shall be equipped with necessary devices to record quantities, by classification or other identification, of hazardous wastes deposited into the facility system.
C. Each site shall be equipped with a central control and recordkeeping system which tabulates information from LAC 33:V.1527.A.2 and B.
D. Onsite Transfer Systems
1. All docking, mooring, loading, and unloading facilities for a hazardous waste treatment, storage, or disposal facility are considered part of the facility operation.
2. Hose couplings for truck, barge, or pipeline discharge shall be located within a natural or created containment, with an elevation above surface elevation sufficient to contain a 10-minute discharge. Groundwater protection shall be provided.
3. Hose couplings on a barge shall be in a containment area on the barge to prevent leakage from entering the waterway.
4. Hoses from a barge to the facility shall be supported by a land-based boom so that the low point of the hose is within the barge or site containment area.
5. Barge moorings shall be in a slack water area outside the navigation channel.
E. Receiving Waste from an Offsite Source. The owner or operator of a facility that receives hazardous waste from an off site source (except where the owner or operator is also the generator) must inform the generator in writing that he has the appropriate permit(s) for, and will accept, the waste the generator is shipping. The owner or operator must keep a copy of this written notice as part of the operating record.
F. Unmanifested Waste Reports. Any wastes presented for disposal that are not accompanied by a properly completed manifest shall be rejected. The TSD operator shall note the name of the driver, hauler, and the vehicle identification numbers. He shall notify SPOC by phone immediately and in writing within seven days of the refusal to accept the waste and provide the administrative authority with the required information.

La. Admin. Code tit. 33, § V-1527

Promulgated by the Department of Environmental Quality, Office of Solid and Hazardous Waste, Hazardous Waste Division, LR 10:200 (March 1984), amended by the Office of Environmental Assessment, Environmental Planning Division, LR 26:2472 (November 2000), amended by the Office of the Secretary, Legal Affairs Division, LR 31:2456 (October 2005), LR 33:2104 (October 2007).
AUTHORITY NOTE: Promulgated in accordance with R.S. 30:2180 et seq.