A.
1. The owner or operator must inspect his facility for malfunctions and deterioration, operator errors, and discharges which may be causing or may lead to:
a. a release of hazardous waste; or
b. a threat to human health.
2. The owner or operator must conduct these inspections often enough to identify problems in time to correct them before they harm human health or the environment.
B. Inspection Schedule
1. The owner or operator must develop and follow a written schedule for inspecting monitoring equipment, safety and emergency equipment, security devices, and operating and structural equipment (such as dikes and sump pumps) that are important to preventing, detecting, or responding to environmental or human health hazards.
2. He must keep this schedule at the facility.
3. The schedule must identify the types of problems (e.g., malfunctions or deterioration) which are to be looked for during the inspection (e.g., inoperative sump pump, leaking fitting, eroding dike, etc.).
4. The frequency of inspection may vary for the items on the schedule. However, the frequency should be based on the rate of possible deterioration of the equipment and the probability of an environmental or human health incident if the deterioration, a malfunction, or operator error goes undetected between inspections. Areas subject to spills, such as loading and unloading areas, must be inspected daily when in use. At a minimum, the inspection schedule must include the items and frequencies called for in LAC 33:V.1709, 1719, 1721, 1731, 1753, 1755, 1757, 1759, 1761, 1763, 1765, 1907, 1911, 2109, 2309, 2507, 2711, 2907, 3119, and 3205, where applicable. LAC 33:V.517.G requires the inspection schedule to be submitted with Part II of the permit application. The department will evaluate the schedule along with the rest of the application to ensure that it adequately protects human health and the environment. As part of this review, the department may modify or amend the schedule as may be necessary.
C. The owner or operator must remedy any deterioration or malfunction of equipment or structures which the inspection reveals; a schedule must be set up to ensure that the problem does not lead to an environmental or human health hazard. When a hazard is imminent or has already occurred, remedial action must be taken immediately.
D. The owner or operator must record inspections in an inspection log or summary. He must keep these records for at least three years from the date of inspection. At a minimum, these records must include the date and time of the inspection, the name of the inspector, a notation of the observations made, and the date and nature of any repairs or other remedial actions.

La. Admin. Code tit. 33, § V-1509

Promulgated by the Department of Environmental Quality, Office of Solid and Hazardous Waste, Hazardous Waste Division, LR 10:200 (March 1984), amended LR 17:658 (July 1991), LR 18:1256 (November 1992), LR 21:266 (March 1995), amended by the Office of Waste Services, Hazardous Waste Division, LR 24:1695 (September 1998), LR 25:437 (March 1999), amended by the Office of the Secretary, Legal Affairs Division, LR 34:993 (June 2008), Amended by the Office of the Secretary, Legal Affairs and Criminal Investigations Division, LR 46931 (7/1/2020).
AUTHORITY NOTE: Promulgated in accordance with R.S. 30:2180 et seq.