La. Admin. Code tit. 33 § V-517

Current through Register Vol. 50, No. 9, September 20, 2024
Section V-517 - Part II Information Requirements (the Formal Permit Application)

The formal permit application information requirements presented in this Section reflect the standards promulgated in LAC 33:V.Subpart 1. These information requirements are necessary in order to determine compliance with all standards. Responses and exhibits shall be numbered sequentially according to the technical standards. The permit application must describe how the facility will comply with each of the Sections of LAC 33:V.Chapters 15-37 and 41. Information required in the formal permit application shall be submitted to the administrative authority and signed in accordance with requirements in LAC 33:V.509. The description must include appropriate design information (calculations, drawings, specifications, data, etc.) and administrative details (plans, flow charts, decision trees, manpower projections, operating instructions, etc.) to permit the administrative authority to determine the adequacy of the hazardous waste permit application. Certain technical data, such as design drawings, specifications, and engineering studies, shall be certified by a Louisiana registered professional engineer. If a Section does not apply, the permit application must state it does not apply and why it does not apply. This information is to be submitted using the same numbering system and in the same order used in these regulations:

A. a general description of the facility including hours of operation/day and days/week;
B. a topographic map or maps showing a distance of 1,000 feet around the facility at a scale of 2.5 centimeters (1 inch) equal to not more than 61.0 meters (200 feet); contours must be shown on the map. The contour interval must be sufficient to clearly show the pattern of surface water flow in the vicinity of and from each operational unit of the facility. The map or maps shall clearly show the following:
1. map scale and date;
2. orientation of the map (north arrow);
3. 100-year floodplain area;

COMMENT: Owners and operators of all facilities shall provide an identification of whether the facility is located within a 100-year floodplain and a flood hazard map (Corps of Engineers or Department of Housing and Urban Development). This identification must indicate the source of data for such determination and include a copy of the relevant Federal Insurance Administration (FIA) flood map, if used. Where maps for the National Flood Insurance Program produced by FIA of the Federal Emergency Management Agency are available, they will normally be determinative of whether a facility is located within or outside of the 100-year floodplain. However, where the FIA map excludes an area (usually areas of the floodplain less than 200 feet in width), these areas must be considered and a determination made as to whether they are in the 100-year floodplain. Where FIA maps are not available for a proposed facility location, the owner or operator must use equivalent mapping techniques to determine if the facility is within the 100-year floodplain, and if so located, what the 100-year flood elevation would be.

4. surface waters including intermittent streams and surface flow through the site and a map of the potentiometric surface for aquifers within 100 feet of lowest elevation of disposal cells, or other facilities containing hazardous waste, from 1,000 feet upstream to 1,000 feet downstream, where practicable. Included should be a general area map and cross sections indicating the extent of freshwater sands, and the degree of isolation from waste sources by confining layers of clay;
5. surrounding land uses (residential, commercial, agricultural, recreational, public) such as schools, day care centers, hospitals, nursing homes, prisons, libraries, etc.;

COMMENT: A map or aerial photograph showing surrounding land use for the area within 2 miles of the site is required.

6. legal boundaries of the TSD facility site;
7. access control (fences, gates);
8. injection and withdrawal wells both on site and off site;

COMMENT: A map of all known wells, operating or abandoned, on the site and within 2 miles of the site perimeter as required in LAC 33:V.515.A.15, including the depth of wells, amount of pumpage, water level depth (annual maximum and minimum), and water analysis from the water well nearest the disposal site is also required.

9. the proposed location of groundwater monitoring wells as required under LAC 33:V.3315.A and B;
10. the proposed point of compliance as defined under LAC 33:V.3311;
11. buildings, treatment, storage, or disposal operations; or other structures (recreation areas, runoff control systems, access and internal roads, storm sanitary, and process sewerage systems, loading and unloading areas, fire control facilities, utilities, security facilities, etc.);
12. barriers for drainage or flood control;
13. location of operational units within the TSD facility site, where hazardous waste is (or will be) treated, stored, or disposed of (including equipment cleanup areas). (For large TSD facilities, the administrative authority may allow the use of other scales on a case-by-case basis); and
14. natural features affecting off-site drainage patterns, transportation, utilities, and location of effluent discharges;
C. site layout and facility design when phased construction is planned; the plans must indicate each phase and an accompanying schedule of construction;
D. chemical and physical analyses of the hazardous wastes and the hazardous debris to be handled at the facility. At a minimum, these analyses shall contain all the information that must be known to treat, store, or dispose of the wastes properly;
E. a copy of the waste analysis plan required by LAC 33:V.1519.B;
F. a description of the security procedures (including entry control, hours manned, lighting, monitoring, and other procedures to prevent unauthorized entry) and equipment required by LAC 33:V.1507 or a justification demonstrating the reasons for requesting a waiver of this requirement;
G. a copy of the general inspection schedule required by LAC 33:V.1509.B. Include, where applicable, as part of the inspection schedule, specific requirements in LAC 33:V.1709, 1719, 1721, 1731, 1755-1759, 1763, 1907.I, 1911, 2109, 2309, 2507, 2703.A-G, 2907, 3119.B and C, and 3205;
H. a justification of any request for a waiver(s) of the preparedness and prevention requirements of LAC 33:V.1511;
I. a copy of the contingency plan required by LAC 33:V.1513;

[NOTE: Include, where applicable, as part of the contingency plan, specific requirements in LAC 33:V.2909];

J. a description of procedures, structures, or equipment used at the facility to:
1. prevent hazards in unloading operations (for example, ramps, special forklifts);
2. prevent runoff from hazardous waste handling areas to other areas of the facility or environment, or to prevent flooding (for example, berms, dikes, trenches);
3. monitoring leachate control;
4. prevent contamination of water supplies;
5. monitor water and air pollution affecting area outside site;
6. mitigate effects of equipment failure, power outages, inclement weather, or other abnormal conditions;
7. prevent undue exposure of personnel to hazardous waste (for example, protective clothing);
8. prevent accidental ignition or reaction of ignitable, reactive, or incompatible wastes as required to demonstrate compliance with LAC 33:V.1517; and
9. prevent nonpermitted releases to the atmosphere;
K. traffic pattern, estimated volume (number, types of vehicles) and control (for example, show turns across traffic lanes, and stacking lanes, if appropriate; describe access road surfacing and load bearing capacity; show traffic control signals);
L. an outline of both the introductory and continuing training programs by owners or operators to prepare persons to operate or maintain the TSD facility in a safe manner as required to demonstrate compliance with LAC 33:V.1515. A list of general qualifications of key operating positions and a brief description of how training will be designed to meet actual job tasks in accordance with these requirements;
M. a copy of the closure plan and, where applicable, the post-closure plan required by LAC 33:V.3511, 3523, and 1915. Include, where applicable, as part of the plans, specific requirements in LAC 33:V.1915, 2117, 2315, 2521, 2719, 2911, 3121, 3203 and 3207;
N. for hazardous waste disposal units that have been closed, documentation that notices required in LAC 33:V.3517 have been filed;
O. the most recent closure cost estimate for the facility prepared in accordance with LAC 33:V.3705 and a copy of the documentation required to demonstrate financial assurance under LAC 33:V.3707. For a new facility, a copy of the required documentation may be submitted 60 days prior to the initial receipt of hazardous wastes, if that is later than the submission of the Part II;
P. where applicable, the most recent post-closure cost estimate for the facility prepared in accordance with LAC 33:V.3709 plus a copy of the documentation required to demonstrate financial assurance under LAC 33:V.3711. For a new facility, a copy of the required documentation may be submitted 60 days prior to the initial receipt of hazardous wastes, if that is later than the submission of the Part II;
Q. where applicable, a copy of the insurance policy or other documentation which comprises compliance with the requirements of LAC 33:V. Chapter 37. For a new facility, documentation showing the amount of insurance meeting the specification of LAC 33:V. Chapter 37 that the owner or operator plans to have in effect before initial receipt of hazardous waste for treatment, storage, or disposal;
R. where appropriate, proof of coverage by a state financial mechanism in compliance with LAC 33:V. Chapter 37;
S. a wind rose (i.e., prevailing wind speed and direction) and the source of the information;
T. facility location information:
1. seismic standard. In order to determine the applicability of the seismic standard, LAC 33:V.1503.A.3, the owner or operator of the facility must identify the political jurisdiction (e.g., parish, township, or election district) in which the facility is proposed to be located:
a. the owner or operator shall demonstrate compliance with the seismic standard. This demonstration may be made using either published geologic data (including federal hazardous waste regulations) or data obtained from field investigations carried out by the applicant. The information provided must be of such quality to be acceptable to geologists experienced in identifying and evaluating seismic activity. The information submitted must show that either:
i. no faults which have had displacement in Holocene time are present, or no lineations which suggest the presence of a fault (which have displacement in Holocene time) within 3,000 feet of a facility are present, based on data from:
(a). published geologic studies, including cites from federal regulations which demonstrate that the requirements of this Section do not apply;
(b). aerial reconnaissance of the area within a 5-mile radius from the facility;
(c). an analysis of aerial photographs covering a 3,000-foot radius of the facility; and
(d). if needed to clarify the above data, a reconnaissance based on walking portions of the area within 3,000 feet of the facility; or
ii. no faults may pass within 200 feet of the portions of the facility where treatment, storage, or disposal of hazardous waste will be conducted based on data from a comprehensive geologic analysis of the site. Unless a site analysis is otherwise conclusive concerning the absence of faults within 200 feet of such portions of the facility, data shall be obtained from a subsurface exploration (trenching) of the area within a distance no less than 200 feet from portions of the facility where treatment, storage, or disposal of hazardous waste will be conducted. Such trenching shall be performed in a direction that is perpendicular to known faults (which have had displacement in Holocene time) passing within 3,000 feet of the portions of the facility where treatment, storage, or disposal of hazardous waste will be conducted. Such investigation shall document with supporting maps and other analyses, the location of any faults found, and shall be certified by an independent Louisiana registered professional engineer or geologist;
2. 100-year floodplain:
a. owners and operators of all facilities shall provide an identification of whether the facility is located within a 100-year floodplain;
b. owners and operators of facilities located in the 100-year floodplain must provide the following information:
i. the 100-year flood level and any other special flooding factors (e.g., wave action) which must be considered in designing, constructing, operating, or maintaining the facility to withstand washout from a 100-year flood;
ii. engineering analysis to indicate the various hydrodynamic and hydrostatic forces expected to result at the site as a consequence of a 100-year flood;
iii. structural or other engineering studies showing the design of operational units (e.g., tanks, incinerators) and flood protection devices (e.g., floodwalls, dikes) at the facility and how these will prevent washout;
iv. if applicable, and in lieu of the above two provisions, a detailed description of procedures to be followed to remove hazardous waste to safety before the facility is flooded, including:
v. timing of such movement relative to flood levels, including estimated time to move the waste, showing that such movement can be completed before floodwaters reach the facility;
vi. a description of the location(s) to which the waste will be moved and demonstration that those facilities will be eligible to receive hazardous waste in accordance with LAC 33:V.Subpart 1;
vii. the planned procedures, equipment, and personnel to be used and the means to ensure that such resources will be available in time for use; and
viii. the potential for accidental discharges of the waste during movement;
c. existing facilities not in compliance with LAC 33:V.1503.B.3 shall provide a plan showing how the facility will be brought into compliance and a schedule for compliance;
3. site geology, including:
a. certification by a geologist or independent Louisiana registered professional engineer specializing in geotechnical engineering that the ground and subsurface conditions at the site are acceptable for the planned purposes of the facility;
b. identification of the uppermost aquifer and aquifers hydraulically interconnected beneath the facility property, including groundwater flow direction and rate, and the basis for such identification (i.e., the information obtained from hydrogeologic investigations of the facility area);
c. soil types, textures, and conditions to depth of 30 feet below lowest elevation of planned disposal cells for impoundments, landfill and land treatment facility based on test holes at 200-foot intervals (or greater or less intervals if acceptable to the administrative authority);
d. logs of test holes and wells, including soil samples for each pertinent strata analyzed for soil type, texture, permeability, and other pertinent characteristics;
e. general area map and cross sections indicating the extent of freshwater sands, and the degree of isolation of these aquifers to a depth of 1,000 feet from waste sources by confining layers of clay;
f. on a topographic map, a delineation of the waste management area, the property boundary, the proposed point of compliance as defined under LAC 33:V.3311, the proposed location of groundwater monitoring wells as required under LAC 33:V.3315.A and B; and
g. detailed plans and an engineering report describing the proposed groundwater monitoring program to be implemented to meet the requirements of LAC 33:V.3315.A-H;
4. site hydrology, including:
a. travel times in feet/day for normal drainage of each natural surface drainage system within 1,000 feet of the property;
b. climate factors:
i. the 24-hour/25-year storm rainfall;
ii. maximum, minimum, and average temperature/month for past 10 years;
iii. impact of previous hurricanes on area;
iv. comparison of rainfall and evapotranspiration rates; and
v. prevailing wind direction (provide wind rose);
c. a description of any plume of contamination that has entered the groundwater from a regulated unit at the time that the application is submitted that:
i. delineates the extent of the plume on the topographic map such as required under LAC 33:V.517.B; and
ii. identifies the concentration of each LAC 33:V.3325, Table 4 constituent throughout the plume or identifies the maximum concentrations of each such constituent in the plume;
d. if the presence of hazardous constituents have not been detected in the groundwater at the time of permit application, the owner or operator must submit sufficient information, supporting data, and analyses to establish a detection monitoring program which meets the requirements of LAC 33:V.3317. This submission must address the following items specified under LAC 33:V.3317:
i. a proposed list of indicator parameters, waste constituents, or reaction products that can provide a reliable indication of the presence of hazardous constituents in the groundwater;
ii. a proposed groundwater monitoring system;
iii. background values for each proposed monitoring parameter or constituent, or procedures to calculate such values; and
iv. a description of proposed sampling, analysis, and statistical comparison procedures to be utilized in evaluating groundwater monitoring data;
e. if the presence of hazardous constituents has been detected in the groundwater at the point of compliance at the time of permit application, the owner or operator must submit sufficient information, supporting data, and analyses to establish a compliance monitoring program which meets the requirements of LAC 33:V.3319. The owner or operator must also submit an engineering feasibility plan for a corrective action program necessary to meet the requirements of LAC 33:V.3321. To demonstrate compliance with LAC 33:V.3319, the owner or operator must address the following items:
i. a description of the wastes previously handled at the facility;
ii. a characterization of the contaminated groundwater, including concentrations of hazardous constituents;
iii. a list of hazardous constituents for which compliance monitoring will be undertaken in accordance with LAC 33:V.3315 and 3317;
iv. proposed concentration limits for each hazardous constituent, based on the criteria set forth in LAC 33:V.3309.A, including a justification for establishing any alternate concentration limits;
v. detailed plans and an engineering report describing the proposed groundwater monitoring system, in accordance with the requirements of LAC 33:V.3315; and
vi. a description of proposed sampling, analysis, and statistical comparison procedures to be utilized in evaluating groundwater monitoring data;
f. if hazardous constituents have been measured in the groundwater which exceed the concentration limits established under LAC 33:V.3309, Table 1, or if groundwater monitoring conducted at the time of permit application under LAC 33:V.3301-3309 at the waste boundary indicates the presence of hazardous constituents from the facility in groundwater over background concentrations, the owner or operator must submit sufficient information, supporting data, and analyses to establish a corrective action program which meets the requirements of LAC 33:V.3321. To demonstrate compliance with LAC 33:V.3321, the owner or operator must address, at a minimum, the following items:
i. a characterization of the contaminated groundwater, including concentrations of hazardous constituents;
ii. the concentration limit for each hazardous constituent found in the groundwater as set forth in LAC 33:V.3309;
iii. detailed plans and an engineering report describing the corrective action to be taken; and
iv. a description of how the groundwater monitoring program will demonstrate the adequacy of the corrective action;
5. environmental factors, including:
a. list all known historical sites, recreational areas, archaeological sites, wildlife areas, swamps and marshes, habitats for endangered species, and other sensitive ecological areas within 1000 feet of the site; and
b. indicate measures planned to protect such areas listed from detrimental impact from the operation of the proposed facility;
6. geographical factors. For an area within 2 miles of the proposed site, provide the following information:
a. map or aerial photograph showing all buildings identified as residential, commercial, industrial, or public (schools, day care centers, hospitals, nursing homes, prisons, libraries, etc.);
b. population;
c. principal livelihood of residents for facilities located in rural areas;
d. land use; and
e. road network, with average daily traffic count and route of trucks which will transport waste to the facility;
7. operations plan, including:
a. classification and estimated quantities of wastes to be handled;
b. methods and processes utilized:
i. facility capacity for each disposal method;
ii. detailed description of each process or method;
iii. storage and disposal procedures:
(a). plans for receipt, checking, processing, segregation of incompatible wastes, and odor control; and
(b). life of each facility based on projected use;
(c). describe recordkeeping procedures, types of records to be kept, and use of the records by management to control the operation; and
(d). monitoring and recording of incoming wastes;
U. Special Requirements. Administrative authority may require additional provisions for special procedures or processes, for specific information for a supplementary environmental analysis, or for such information as may be necessary to enable the administrative authority to carry out his duties under other state laws;
V. for land disposal facilities, if an approval has been granted under LAC 33:V.2239, a petition has been approved under LAC 33:V.2241 or 2271, or a determination made under LAC 33:V.2273, a copy of the notice of approval or a determination is required; and
W. a summary of the preapplication meeting, along with a list of attendees and their addresses, and copies of any written comments or materials submitted at the meeting, as required under LAC 33:V.708.A.3.

La. Admin. Code tit. 33, § V-517

Promulgated by the Department of Environmental Quality, Office of Solid and Hazardous Waste, Hazardous Waste Division, LR 10:200 (March 1984), amended LR 10:280 (April 1984), LR 13:433 (August 1987), LR 14:790 (November 1988), LR 15:181 (March 1989), LR 15:378 (May 1989), LR 16:220 (March 1990), LR 16:399 (May 1990), LR 16:614 (July 1990), LR 16:683 (August 1990), LR 17:658 (July 1991), LR 18:1256 (November 1992), LR 21:266 (March 1995), amended by the Office of Waste Services, Hazardous Waste Division, LR 24:657 (April 1998), LR 24:1691 (September 1998), LR 25:436 (March 1999), amended by the Office of Environmental Assessment, Environmental Planning Division, LR 25:1465 (August 1999), LR 25:1799 (October 1999), repromulgated LR 26:1608 (August 2000), repromulgated LR 26:2003 (September 2000), amended LR 27:287 (March 2001), amended by the Office of the Secretary, Legal Affairs Division, LR 33:1625 (August 2007), Amended by the Office of the Secretary, Legal Division, LR 431139 (6/1/2017).
AUTHORITY NOTE: Promulgated in accordance with R.S. 30:2180 et seq.