La. Admin. Code tit. 33 § V-4320

Current through Register Vol. 50, No. 11, November 20, 2024
Section V-4320 - Construction Quality Assurance Program
A. CQA Program
1. A construction quality assurance (CQA) program is required for all surface impoundment, waste pile, and landfill units that are required to comply with LAC 33:V.4462.A, 4476, and 4512.A. The program must ensure that the constructed unit meets or exceeds all design criteria and specifications in the permit. The program must be developed and implemented under the direction of a CQA officer who is a registered professional engineer.
2. The CQA program must address the following physical components, where applicable:
a. foundations;
b. dikes;
c. low-permeability soil liners;
d. geomembranes (flexible membrane liners);
e. leachate collection and removal systems and leak detection systems; and
f. final cover systems.
B. Written CQA Plan. Before construction begins on a unit subject to the CQA program under LAC 33:V.4320.A, the owner or operator must develop a written CQA plan. The plan must identify steps that will be used to monitor and document the quality of materials and the condition and manner of their installation. The CQA plan must include:
1. identification of applicable units and a description of how they will be constructed;
2. identification of key personnel in the development and implementation of the CQA plan, and CQA officer qualifications; and
3. a description of inspection and sampling activities for all unit components identified in LAC 33:V.4320.A.2, including observations and tests that will be used before, during, and after construction to ensure that the construction materials and the installed unit components meet the design specifications. The description must cover sampling size and locations, frequency of testing, data evaluation procedures, acceptance and rejection criteria for construction materials, plans for implementing corrective measures, and data or other information to be recorded and retained in the operating record under LAC 33:V.4357.
C. Contents of Program
1. The CQA program must include observations, inspections, tests, and measurements sufficient to ensure:
a. structural stability and integrity of all components of the unit identified in LAC 33:V.4320.A.2;
b. proper construction of all components of the liners, leachate collection and removal system, leak detection system, and final cover system, according to permit specifications and good engineering practices and proper installation of all components (e.g., pipes) according to design specifications; and
c. conformity of all materials used with design and other material specifications under LAC 33:V.2303, 2503, and 2903.
2. The CQA program shall include test fills for compacted soil liners, using the same compaction methods as in the full-scale unit, to ensure that the liners are constructed to meet the hydraulic conductivity requirements of LAC 33:V.2303.C.1, 2503.L.1, and 2903.J.1 in the field. Compliance with the hydraulic conductivity requirements must be verified by using in situ testing on the constructed test fill. The test fill requirement is waived where data are sufficient to show that a constructed soil liner meets the hydraulic conductivity requirements of LAC 33:V.2303.C.1, 2503.L.1, and 2903.J.1 in the field.
D. Certification. The owner or operator of units subject to this Section must submit to the Office of Environmental Services, by certified mail or hand delivery, at least 30 days prior to receiving waste, a certification signed by the CQA officer that the CQA plan has been successfully carried out and that the unit meets the requirements of LAC 33:V.4462.A, 4476, or 4512.A. The owner or operator may receive waste in the unit after 30 days from the administrative authority's receipt of the CQA certification unless the administrative authority determines in writing that the construction is not acceptable, or extends the review period for a maximum of 30 more days, or seeks additional information from the owner or operator during this period. Documentation supporting the CQA officer's certification must be furnished to the administrative authority upon request.

La. Admin. Code tit. 33, § V-4320

Promulgated by the Department of Environmental Quality, Office of Solid and Hazardous Waste, Hazardous Waste Division, LR 21:266 (March 1995), amended by the Office of Environmental Assessment, Environmental Planning Division, LR 26:2499 (November 2000), amended by the Office of the Secretary, Legal Affairs Division, LR 31:2475 (October 2005), LR 33:2126 (October 2007).
AUTHORITY NOTE: Promulgated in accordance with R.S. 30:2180 et seq.