Section V-2807 - Inspections
A. During construction or installation, liners and cover systems (e.g., membranes, sheets, or coatings) must be inspected for uniformity, damage, and imperfections (e.g., holes, cracks, thin spots, or foreign materials). Immediately after construction or installation, liners must be inspected and certified as meeting the requirements of LAC 33:V.2805 by an independent, qualified professional engineer. The certification must be maintained at the facility as part of the facility operating record. After installation, liners and covers must be inspected to ensure tight seams and joints and the absence of tears, punctures, or blisters.
B. While a drip pad is in operation, it must be inspected weekly and after storms to detect evidence of any of the following:
1. deterioration, malfunctions or improper operation of run-on and run-off control systems;
2. the presence of leakage in and proper functioning of leak detection system;
3. deterioration or cracking of the drip pad surface.

La. Admin. Code tit. 33, § V-2807

Promulgated by the Department of Environmental Quality, Office of Solid and Hazardous Waste, Hazardous Waste Division, LR 18:1375 (December 1992), amended LR 21:944 (September 1995), amended by the Office of the Secretary, Legal Affairs Division, LR 34:999 (June 2008).

AUTHORITY NOTE: Promulgated in accordance with R.S. 30:2180 et seq.

NOTE: See LAC 33:V.2805.N for remedial action required if deterioration or leakage is detected.