Current through Register Vol. 50, No. 9, September 20, 2024
Section V-1741 - Test Methods and ProceduresA. Each owner or operator subject to the provisions of this Subchapter shall comply with the test methods and procedures requirements provided in this Section.B. Leak detection monitoring, as required in LAC 33:V.1719-1739, shall comply with the following requirements. 1. Monitoring shall comply with Reference Method 21 in 40 CFR Part 60, Appendix A, incorporated by reference in LAC 33:III.3003.2. The detection instrument shall meet the performance criteria of Reference Method 21.3. The instrument shall be calibrated before use on each day of its use by the procedures specified in Reference Method 21.4. Calibration gases shall be: a. zero air (less than 10 ppm of hydrocarbon in air); andb. a mixture of methane or n-hexane and air at a concentration of approximately, but less than, 10,000 ppm methane or n-hexane.5. The instrument probe shall be traversed around all potential leak interfaces as close to the interface as possible as described in Reference Method 21.C. When equipment is tested for compliance with no detectable emissions, as required in LAC 33:V.1719.E, 1721.I, 1723, and 1729.F, the test shall comply with the following requirements. 1. The requirements of LAC 33:V.1741.B.1-4 shall apply.2. The background level shall be determined as set forth in Reference Method 21.3. The instrument probe shall be traversed around all potential leak interfaces as close to the interface as possible as described in Reference Method 21.4. The arithmetic difference between the maximum concentration indicated by the instrument and the background level is compared with 500 ppm for determining compliance.D. In accordance with the waste analysis plan required by LAC 33:V.1519.B, an owner or operator of a facility must determine, for each piece of equipment, whether the equipment contains or contacts a hazardous waste with organic concentration that equals or exceeds 10 percent by weight using the following: 1. methods described in ASTM Methods D 2267-88, E 169-87, E 168-88, E 260-85, as incorporated by reference at LAC 33:V.110;2. Method 9060A (incorporated by reference in LAC 33:V.110) of Test Methods for Evaluating Solid Waste, Physical/Chemical Methods, EPA Publication SW-846, for computing total organic concentration of the sample or analyzing for its individual organic constituents; or3. application of the knowledge of the nature of the hazardous waste stream or the process by which it was produced. A waste determination by knowledge must be documented. Examples of documentation that shall be used to support a determination under this provision include production process information documenting that no organic compounds are used, information that the waste is generated by a process that is identical to a process at the same or another facility that has previously been demonstrated by direct measurement to have a total organic content less than 10 percent, or prior speciation analysis results on the same waste stream where it can also be documented that no process changes have occurred since that analysis that could affect the waste total organic concentration.E. If an owner or operator determines that a piece of equipment contains or contacts a hazardous waste with organic concentrations at least 10 percent by weight, the determinations can be revised only after following the procedures in LAC 33:V.1741.D.1 or 2.F. When an owner or operator and the administrative authority do not agree on whether a piece of equipment contains or contacts a hazardous waste with organic concentrations at least 10 percent by weight, the procedures in LAC 33:V.1741.D.1 or 2 can be used to resolve the dispute.G. Samples used in determining the percentage organic content shall be representative of the highest total organic content hazardous waste that is expected to be contained in or contact the equipment.H. To determine whether pumps or valves are in light liquid service, the vapor pressures of constituents may be obtained from standard reference texts or may be determined by ASTM D-2879-86, as incorporated by reference at LAC 33:V.110.I. Performance tests to determine whether a control device achieves 95 weight percent organic emission reduction shall comply with the procedures of LAC 33:V.1711.C.1-4.La. Admin. Code tit. 33, § V-1741
Promulgated by the Department of Environmental Quality, Office of Solid and Hazardous Waste, Hazardous Waste Division, LR 17:658 (July 1991), amended LR 20:1000 (September 1994), LR 22:819 (September 1996), amended by the Office of Waste Services, Hazardous Waste Division, LR 24:1701 (September 1998), amended by the Office of the Secretary, Legal Affairs Division, LR 34:1013 (June 2008), LR 34:1896 (September 2008).AUTHORITY NOTE: Promulgated in accordance with R.S. 30:2180 et seq.