C. Any affected source must use one of the following four protocols to measure capture efficiency, unless a suitable alternative protocol is approved by the administrative authority*. 1. Gas/Gas Method Using TTE. The specifications to determine whether a temporary enclosure is considered a TTE are given in 40 CFR, Part 51, Appendix M, Method 204, Section 5. The capture efficiency equation to be used for this protocol is: Click Here To View Image
CE = capture efficiency, decimal fraction
Gw = mass of VOC captured and delivered to control device using a TTE
Fw = mass of fugitive VOC that escapes from a TTE
NOTE: 40 CFR, Part 51, Appendix M, Method 204C, Section 9 is used to obtain Gw. 40 CFR, Part 51, Appendix M, Method 204D, Section 9 is used to obtain Fw.
2. Liquid/Gas Method Using TTE. The specifications to determine whether a temporary enclosure is considered a TTE are given in 40 CFR, Part 51, Appendix M, Method 204, Section 5. The capture efficiency equation to be used for this protocol is: Click Here To View Image
CE = capture efficiency, decimal fraction
L = mass of liquid VOC input to process
F = mass of fugitive VOC that escapes from a TTE
NOTE: 40 CFR, Part 51, Appendix M, Method 204, Section A.10 is used to obtain L. 40 CFR, Part 51, Appendix M, Method 204D, Section 9 is used to obtain F.
3. Gas/Gas Method Using the Building or Room (BE) in which the Affected Source is Located as the Enclosure and in which G and F are Measured while Operating only the Affected Facility. All fans and blowers in the building or room must be operated as they would under normal production. The capture efficiency equation to be used for this protocol is: Click Here To View Image
CE = capture efficiency, decimal fraction
G = mass of VOC captured and delivered to a control device
FB = mass of fugitive VOC that escapes from building enclosure
NOTE: 40 CFR, Part 51, Appendix M, Method 204C, Section 9 is used to obtain G. 40 CFR, Part 51, Appendix M, Method 204E, Section 9 is used to obtain FB.
4. Liquid/Gas Method Using the Building or Room (BE) in which the Affected Source is Located as the Enclosure and in which L and F are Measured while Operating only the Affected Facility. All fans and blowers in the building or room must be operated as they would under normal production. The capture efficiency equation to be used for this protocol is: Click Here To View Image
CE = capture efficiency, decimal fraction
L = mass of liquid VOC input to process
FB = mass of fugitive VOC that escapes from building enclosure
AUTHORITY NOTE: Promulgated in accordance with R.S. 30:2054. NOTE: 40 CFR, Part 51, Appendix M, Method 204, Section A.10 is used to obtain L. 40 CFR, Part 51, Appendix M, Method 204E, Section 9 is used to obtain FB.