RELATES TO: KRS 194A.050(2), 211.015, 211.350-211.380, 211.990(2), Chapter 322
NECESSITY, FUNCTION, AND CONFORMITY: KRS 211.180(1)(d) requires the cabinet to regulate the construction, installation, or alteration of any on-site sewage disposal system, except for a system with a surface discharge, regulated by KRS 224.10-100(19). This administrative regulation establishes uniform standards for on-site sewage disposal systems to assure that the construction, installation, or alteration of an on-site sewage disposal system is performed in such a manner as to protect public health and the environment.
Table 1 Design Daily Waste Flow | ||||
Gallons/Unit/Day | ||||
Source of Sewage Dwelling Units | Units | Standard | Column B | Column C |
Single family residences | Each bedroom | 110 | 83 | 55 |
Hotels or motels | Each room | 90 | ||
Apartments/condominiums/townhouses | Each bedroom | 110 | ||
Rooming houses | Each bedroom | 110 | ||
Mobile home parks | Space | 270 | ||
Commercial/industrial: | ||||
Retail stores | Each toilet room | 180 | ||
Malls, shopping centers | Each 1000 sq. ft. | 180 | ||
Offices and tattoo studios | Employee | 15 | ||
Medical offices (with laboratories) | Employee | 45 | ||
Dental offices (with water rinse units) | Exam chair | 225 | ||
Dental offices (with suction units) | Exam chair | 45 | ||
Veterinary office (add for animal grooming) (add for animal boarding) | Clinic per animal per animal | 2251010 | ||
Dog kennels | per dog | 5 | ||
Industrial buildings (Add for showers) | Employee/shift (does not include process water or cafeteria) Employee/shift | 1510 | ||
Construction site | Employee/shift | 15 | ||
Visitor center | Visitor | 4 | ||
Barber shops | Chair | 65 | ||
Beauty shops | Chair | 115 | ||
Laundromats: (experimental only) | Machine | 300 | ||
Eating and drinking establishments: | ||||
Restaurant (does not include bar or lounge) | Meal/seat | 15 | ||
Bar or lounge | Seat | 15 | ||
Drive-in (no public restrooms) | Establishment | 450 | ||
Drive-in (with public restrooms) | Car stall | 15 | ||
Food markets: | ||||
Prepackaged/Catering | Store or establishment | 225 | ||
Food processing/Retail/Manufacturing: (with eat-in delicatessen)(with carryout delicatessen) | StoreMeal/seatStore | 90015 Additional 225 | ||
Rabbit or fish processors (with solid waste separation) | Employee/shiftper animal or fish processed | 150.5 | ||
Institutional (includes food service): | ||||
Hospitals and surgical centers | Each bed | 270 | ||
Mental | Each bed | 90 | ||
Prison or jail | Each inmate bed | 90 | ||
Nursing home, rest home | Each resident bed | 90 | ||
Schools and Churches (includes food service): | ||||
Elementary, day care, kindergarten | Student | 20 | ||
High school | Student | 30 | ||
College | Student | 30 | ||
Boarding school | Student | 55 | ||
Churches: (without kitchen facilities) (with kitchen facilities) | Average attendance/personAverage attendance/person | 34 | ||
Recreational: | ||||
Recreational vehicle park (sewer hook-ups to each space) (with central bath only) Dump station only | Space Space Space | 1156520 | ||
Day camp (no meals) | Person | 15 | ||
Residential camp (includes cafeteria) | Person | 55 | ||
Resorts/housekeeping cabin | Bedroom | 110 | 83 | 55 |
Tent camping areas w/central bath | Space | 65 | ||
Country clubs (does not include food service) | Member | 10 | ||
Golf courses | Average attendance/person | 8 | ||
Swimming pools | Design capacity/person | 8 | ||
Picnic parks, sports facilities, ball parks: | ||||
(with toilet only) (with food service) | Average attendance/person Average attendance/person | 47 | ||
Movie theaters | Seat | 4 | ||
Drive-in theaters (includes food service) | Space | 12 | ||
Skating rink/dance hall | Person (based on rated capacity) | 8 | ||
Bowling alley | Lane | 90 | ||
Transportation: | ||||
Airport, bus or rail depot | Passenger | 4 | ||
Auto service station | Each water closet or urinal | 225 |
Table 2 Minimum Capacity of Pretreatment Units | ||
Number of Bedrooms | Gallon Capacity (Without Garbage Disposal) | Gallon Capacity (With Garbage Disposal) |
3 or less | 1,000 | 1,250 |
4 | 1,250 | 1,500 |
5 | 1,500 | 1,750 |
Each Additional | 250 | 250 |
Table 3 Application Rates for Gravity Distribution Lateral Fields Based on Two (2) Foot Conventional Trench Width | |||
Soil Group | Soil Texture Classes | Application Rate Gal/Sq. Ft./Day | Linear Ft. Per Gallon |
I Sands | Sand | 1.2 | .42 |
Loamy Sand | .9 | .56 | |
II Coarse loams | Sandy Loam | .7 | .72 |
IIIa. Fine loams (with suitable structure) | Sandy Clay Loam | .5 | 1.0 |
Silt Loam | |||
Silt | |||
Clay Loam | |||
Silty Clay Loam | |||
IIIb. Fine loams (with provisionally suitable structure) | Sandy Clay Loam | .37 | 1.35 |
Silt Loam | |||
Silt | |||
Clay Loam | |||
Silty Clay Loam | |||
IV Clays (Kaolinitic or mixed mineralogy with provisionally suitable structure) | Sandy Clay | .27 | 1.85 |
Silty Clay | |||
Clay |
Table 4 Application Rates for Low Pressure Pipe (LPP) Lateral Fields | ||
Soil Texture Group | Soil Texture Classes | Rate Gal/Sq.Ft./Day |
I Sands | Sand | 0.5 |
Loamy Sand | ||
II Coarse Loams | Sandy Loam | 0.4 |
Loam | ||
IIIa. Fine Loams (with suitable structure) | Sandy Clay Loam | 0.3 |
Silt Loam | ||
Silt | ||
Clay Loam | ||
Silty Clay Loam | ||
IIIb. Fine Loams (with provisionally suitable structure) | Sandy Clay Loam | 0.1714 |
Silt Loam | ||
Silt | ||
Clay Loam | ||
Silty Clay Loam | ||
IV Clays (Kaolinitic or mixed mineralogy with provisionally suitable structure) | Sandy Clay | 0.1 |
Silty Clay | ||
Clay |
Table 5 Lateral Bed Length Requirements for Gravity Distribution Systems Based on Bed Width | |
Bed Width | Multiply Total Linear Footage of Two (2) Foot Wide Trench Required By: |
3' | 70% |
4' | 55% |
5' | 45% |
6' | 40% |
7' | 35% |
8' | 32% |
9' | 30% |
10' | 28% |
11' | 27% |
12' or wider | 26% |
Table 6 Maximum Grades for Trench and Bed Bottoms | ||
Distribution Method | Type | Maximum Gradeinches/200 feet |
Hillside or drop box | Trench | 2" |
Equal Flow Box | Trench | 4" |
Bed | Level to 1" in all directions from center | |
Gravelless Pipe | Trench | Level |
Low Pressure Pipe | Trench | Level |
Bed (Mound) | Level | |
Leaching Chambers (using any of the above methods except low pressure) (using low pressure pipe) | Trench layout | 4" |
Bed Layout | Level | |
Trench | Level |
Table 7 Minimum Setback Distances for On-site Sewage Disposal Systems | ||
Structure or Topographic Feature | Minimum Distance (Ft.) from Pretreatment Unit, Constructed Wetland Cell, or Holding Tank | Minimum Distance (Ft.) from Side wall of Lateral Trench, Bed, or Lagoon |
Property lines | 5 | 5 (50 for lagoons) |
Building foundations | 10 | 10 |
Basements, cemeteries | 20 | 20 |
Basements (Downslope from system) | 20 | 30 (5-15% Slope) 40 (15-25% Slope) 50 (25% and Higher) |
Wells | 50 | 70 |
Wells (Properly plugged/abandoned) | 20 | 20 |
Cisterns | 50 | 70 |
Cisterns (Upslope from system with bottom at higher elevation than system) | 10 | 10 |
Natural Lakes or Impoundments (Shoreline) | 25 | 50 |
Streams | 25 | 25 |
Springs (Upslope from system) | 25 | 50 |
(Upslope with curtain interceptor drain) | 10 | 20 |
(Downslope from system) | 50 | 70 |
Drainage Ditches, Cutbanks (Downslope) | 10 | 25 |
Curtain or vertical drain (Upslope and Sides) (Downslope) | 10 | 1025 |
Sinkhole Throat (Open) | 70 | 70 |
Buried Water Lines or Utility Lines | 10 | 10 |
Utility Easements | 10 | 10 |
Driveways, parking lots, or paved areas | 10 | 5 |
Geothermal Vertical | 50 | 70 |
Geothermal Horizontal (Downslope) | 10 | 10 (upslope and sides) 25 |
Inground swimming pools | 10 | 20 |
Mine Openings and Air Shafts | 50 | 70 |
Livestock pens, feed lots, corrals, etc. | 10 | 10 |
902 KAR 10:085
STATUTORY AUTHORITY: KRS 194A.050(1), 211.090(3), 211.180(1)(d), 211.350, 211.351