RELATES TO: KRS 351.330
NECESSITY, FUNCTION, AND CONFORMITY: KRS 351.330 requires the Department for Natural Resources to limit ground vibrations. This administrative regulation effects the provisions of that law.
V = Vo (Do/D) 1.5
Where Vo is the maximum ground particle velocity at the seismograph, Do is the distance of the seismograph from the blast, and D is the distance from the blast to the position in question and in the same general direction. The distance Do may not be greater than D, and D cannot be more than five (5) times Do. This determined velocity at the site of any dwelling house, public building, school, church, commercial or institutional building shall not exceed the two (2) inches per second limit.
805 KAR 4:030
STATUTORY AUTHORITY: KRS Chapter 13A, 351.335