Iowa Admin. Code r. 875-73.6

Current through Register Vol. 47, No.14, January 8, 2025
Rule 875-73.6 - [Effective 2/12/2025] Child entrapment safeguard requirements

This rule applies to a passenger elevator unless it has a car door consisting of a solid panel.

(1) For purposes of this rule, "distance with deflection between the doors or gates" means the distance between the closed car door or gate and the closed hoistway door or gate measured at the greatest perpendicular distance with deflection.
(2) For purposes of this rule, measurements of door or gate deflection are made in the manner described by ASME A17.1, section 2.14.4.6.
(3) Door or gate deflection do not exceed .75 inch.
(4) If the distance with deflection between the doors or gates exceeds 5 inches, a means will be provided to disable the elevator if a person is in the space between the closed doors or gates.

Iowa Admin. Code r. 875-73.6

Adopted by IAB January 8, 2025/Volume XLVII, Number 14, effective 2/12/2025