Iowa Admin. Code r. 875-72.26

Current through Register Vol. 47, No. 5, September 4, 2024
Rule 875-72.26 - Child entrapment safeguards

This rule applies to a passenger elevator unless it has a car door consisting of a solid panel.

(1) For purposes of this rule, "distance with deflection between the doors or gates" means the distance between the closed car door or gate and the closed hoistway door or gate measured at the greatest perpendicular distance with deflection.
(2) For purposes of this rule, measurements of door or gate deflection shall be made in the manner described by ASME A17.1, section 2.14.4.6.
(3) Door or gate deflection shall not exceed .75 inch.
(4) If the distance with deflection between the doors or gates exceeds 5 inches, a means shall be provided to disable the elevator if a person is in the space between the closed doors or gates.

Iowa Admin. Code r. 875-72.26

Adopted by IAB April 29, 2015/Volume XXXVII, Number 22, effective 6/3/2015
Amended by IAB March 16, 2016/Volume XXXVIII, Number 19, effective 4/20/2016