Authority: IC 22-13-2-2
Affected: IC 22-11-17-2.5; IC 22-12-7; IC 22-13; IC 22-14; IC 36-8-17
Sec. 11.
Chapter 10 is amended as follows:
Gymnasium floor used exclusively for sports activities Gymnasium floor used for sports activities and other assembly use Spectator seating areas
Gymnasium floor used exclusively for sports activities | 50 grossb |
Gymnasium floor used for sports activities and other assembly use | See Section 1004.4 for seating occupant load factorc |
Spectator seating areas | See Section 1004.4d |
b Used for sporting activities only with no spectator seating or assembly use of the floor.
c Gymnasium floor shall be calculated at 7 s.f. net per person for assembly uses with chairs only, and 15 s.f net per person for assembly use limited to tables and chairs. For gymnasium floor areas used in multiple assembly configurations, a seating and fixed equipment diagram shall be submitted to the Code Official, or the occupant load shall be calculated at 7 s.f. net per person.
d Where spectator seating includes, portable, folding, or retractable systems, the occupant load shall be the greater of the calculated number in all use configurations.
Exception: Access through an intervening room may be permitted if the intervening door is not lockable and an exit sign is installed above the door directing occupants to the fire escape.
COMMON PATH OF EGRESS TRAVEL
Occupancy | Without Sprinkler System (feet) | With Sprinkler System (feet) | |
Occupant Load | |||
<= 30 | > 30 | ||
All others c,f | 75 | 75 | 75 a, b |
EXIT ACCESS TRAVEL DISTANCEa
Occupancy | Without Sprinkler System (feet) | With Sprinkler System (feet) |
I-1 | Not Permitted | 250b |
Exception: Canopies and similar types of building features may be used as a portion of the rescue access system, if the slope of the canopy does not exceed two (2) inches in twelve (12) inches, and access as required in Section 1029 is provided from the ground to the top edge of the canopy.
675 IAC 22-2.5-11