675 Ind. Admin. Code 21-3-2

Current through May 29, 2024
Section 675 IAC 21-3-2 - Amendments to adopted code

Authority: IC 22-13-2-13

Affected: IC 10-19; IC 22-12-1-22; IC 22-12-2-10; IC 22-14; IC 22-15; IC 36-7-2-9; IC 36-8-17-8

Sec. 2.

(a) Explanatory material, in the form of notes, that is not part of a table, figure, or graph, is not:
(1) a part of this standard; and
(2) enforceable as part of this rule.
(b) Delete subsection 1.1.3 in its entirety and substitute the following: 1.1.3 Application of Code:
(a) Except as provided in (b) and (c) below, this Code applies to new installations only.
(b) Part 1 and Section 5.10, Section 8.6, Section 8.7, Section 8.8, Section 8.9, Section 8.10, and Section 8.11 apply to new and existing installations.
(c) Section 8.1 applies to any installation for which an installation permit was received by the Department on or after the effective date of the 2011 amendments to this rule.
(c) Delete subsection 1.1.4, Effective Date, without substitution.
(d) Delete Section 1.2, Purpose and Exceptions, in its entirety and substitute the following: 1.2 Keys. All keys associated with the equipment described in Section 1.1 shall be placed in a heavy metal enclosure. All such keys shall be clearly identified. The enclosure shall be conspicuously located and identified by a sign stating "FOR EMERGENCY USE ONLY". All such enclosures shall be equipped with a seven (7) pin cylindrical lock opened by a common key SI-2. Only responding fire department officers, the authority having jurisdiction, and the elevator contractor shall be permitted to retain keys for such enclosures.
(e) Amend Section 1.3, Definitions, to read as follows:
(1) Add a definition to read as follows: NFPA 70 means the Indiana Electrical Code (675 IAC 17).
(2) Add a definition to read as follows: ANSI A117.1 means the Indiana Building Code, Chapter 11, Part 1 (675 IAC 13).
(3) Add a definition to read as follows: Department means the Indiana Department of Homeland Security created in accordance with IC 10-19.
(4) Add a definition to read as follows: Division means the Division of Fire and Building Safety of the Department.
(5) Change the definition of APPROVED to read as follows: APPROVED means, as to materials, equipment, products, and construction, acceptance by the authority having jurisdiction by one (1) of the following methods:
(A) Investigation or tests conducted by recognized authorities.
(B) Investigation or tests conducted by technical or scientific organizations.
(C) Accepted principles.

The investigation, tests, or principles shall establish that the materials, equipment, products, and construction are safe for their intended purposes.

(6) Change the definition of AUTHORITY HAVING JURISDICTION to read as follows: AUTHORITY HAVING JURISDICTION means the division of fire and building safety, the local building official as authorized under IC 36-7-2-9, and the local ordinance or the fire department as authorized under IC 36-8-17-8.
(7) Change the definition of BUILDING CODE to read as follows: BUILDING CODE means the Indiana Building Code, 675 IAC 13, for Class 1 structures except townhouses or the Indiana Residential Code, 675 IAC 14, for Class 2 structures and townhouses in effect at the time of the construction, addition, or alteration of the building or structure.
(8) Change the definition of CERTIFIED to read as follows: CERTIFIED means "approved".
(9) Change the definition of ELEVATOR to read as follows: ELEVATOR means a regulated lifting device as defined in IC 22-12-1-22.
(10) Change the definition of LABELED/MARKED to read as follows: LABELED means equipment or materials to which has been attached a label, symbol, or other identifying mark of an organization engaged in product evaluation, that maintains periodic inspection of production of labeled equipment or materials, and by whose labeling the manufacturer indicates compliance with appropriate standards or performance in a specified manner.
(11) Change the definition of LISTED/CERTIFIED to read as follows: LISTED. Equipment or materials included in a list published by an organization engaged in product evaluation that maintains periodic inspection of production of listed equipment or materials and whose listing states either that the equipment or material meets appropriate standards or has been tested and found suitable for use in a specified manner.
(12) Change the definition of REGULATORY AUTHORITY to read as follows: REGULATORY Authority:

See AUTHORITY HAVING JURISDICTION.

(f) Delete Section 2.2.2.5 in its entirety without substitution.
(g) Amend Section 3.4.5(b) to insert, after "assemblies", ", any hydraulic jack".
(h) Delete Sections 5.3, 5.4, 5.8, and 5.9 without substitution.
(i) Amend Section 6.1.1.1, Protection Required, to read as follows: Floor openings for escalators shall be protected against the passage of flame, heat, and/or smoke in accordance with the Indiana Building Code, 675 IAC 13.
(j) Amend subsection 6.1.2.1, Protection Required, as follows:
(1) Delete "of NFPA 101, whichever is applicable (see Chapter 9)".
(2) Delete "adequate" and insert "required".
(k) Amend Section 6.2.1.1, Protection Required, to read as follows: Where a moving walk penetrates a building floor, the opening shall be protected against the passage of flame, heat, and/or smoke in accordance with the provisions of the Indiana Building Code, 675 IAC 13.
(l) Amend subsection 6.2.2.1, Protection Required, as follows:
(1) Delete "of NFPA 101, whichever is applicable (see Chapter 9)".
(2) Delete "adequate" and insert "required".
(m) Amend subsection 7.1.1.1 by deleting the second sentence.
(n) Amend subsection 7.1.8.2 as follows: Requirement 2.8.2.3 does not apply. Sprinklers shall be permitted in the hoistway when conforming to NFPA 13 as adopted by the commission at the time of installation of the elevator. All sprinkler risers and returns shall be located outside the hoistway.
(o) Delete Sections 7.4, 7.5, and 7.6 without substitution.
(p) Amend subsection 8.6.1.4.2, Record Availability, as follows: Add "and the AUTHORITY HAVING JURISDICTION" to the end of the section.
(q) Amend the first sentence of Section 8.6.1.5.1 to read as follows: For installations for which installation permit applications were received by the Department on or after January 3, 2003, a data plate that indicates the applicable rule of the commission in effect at the time of installation and any alteration (see 8.7.1.8) shall be provided.
(r) Amend Section 8.6.1.6.3(a) to read as follows: For installations for which installation permit applications were received by the Department on or after January 3, 2003, up-to-date wiring diagrams detailing circuits of all electrical protective devices (see 2.26.2) and critical operating circuits (see 2.26.3), where such diagrams are available from the original equipment manufacturer, shall be available in the machine room.
(s) Amend Section 8.6.3.11 as follows:
(1) Add at the end of the first sentence ", and such replacements shall be subjected to the relief valve setting testing described in Section 8.11.3.2.1".
(2) Add a second sentence as follows: Documentation of such testing shall be maintained with the maintenance records on site for review by the Division.
(t) Amend Section 8.6.5.4 to insert the following at the end of the sentence, "contained in the manufacturer's specifications".
(u) Amend Section 8.6.5.6 to add the following at the end of the section: Such replacements shall be subjected to the relief valve setting testing described in Section 8.11.3.2.1 and Section 8.11.3.2.4. Documentation of such testing shall be maintained with the maintenance records on site for review by the Division.
(v) Amend Section 8.7.2.11.5 to read as follows:
(a) Except as provided in (b) below, where a device that restricts the opening of hoistway doors or car doors is altered or installed, the device shall conform to 2.12.5.
(b) Platform guards shall comply with 2.15.9 to the greater of:
(1) the leveling or truck zone, plus 75 mm (3 in.); or
(2) the extent the existing pit shall permit.
(w) Amend Section 8.7.2.20 to read as follows:
(a) The requirements of 2.19 shall be conformed to where a device for protection against ascending car overspeed and unintended car movement is altered or installed.
(b) The requirements of 2.15.9 shall be conformed to where a device for protection against ascending car overspeed and unintended car movement is altered or installed to the greater of:
(1) the leveling or truck zone, plus 75 mm (3 in.); or
(2) the extent the existing pit shall permit.
(x) Amend Section 8.7.3.23.1 to add, after 3.18, "and 3.19.4.1".
(y) Amend Section 8.7.3.23.3 to add, after 3.18.3, "and 3.19.4.1".
(z) Amend Section 8.7.5.7 to delete "the entire installation" and substitute "only the work contained in the alteration".
(aa) Amend Section 8.7.7.2 in the first sentence to delete "elevator" and insert "material lift".
(bb) Amend subsection 8.10.1.1.1 to read as follows: A licensed inspector must conduct the acceptance inspection. A licensed inspector employed by the enforcement authority may conduct the acceptance inspection. If the enforcement authority chooses not to make this inspection, a third party licensed inspector shall make the acceptance inspection in accordance with the following:
(1) This third party licensed inspector shall sign an attestation for each test that reads, "I hereby attest under penalty for perjury that:
(A) all of the tests required by 8.10.2, 8.10.3, 8.10.4, or 8.10.5 have been completed in my presence by persons qualified to perform such services; and
(B) the regulated lifting device conforms to all applicable building and equipment codes in effect at the time of installation and all applicable building and equipment codes effective as applicable to and for each alteration.".
(2) The third party licensed inspector that performs the acceptance inspection shall not be an employee of the elevator contractor that installed or altered the regulated lifting device or that is performing the required tests.
(cc) Delete Section 8.10.1.1.3 in its entirety without substitution.
(dd) Delete Section 8.10.5.2 in its entirety without substitution.
(ee) Delete Section 8.11.1.1.1 in its entirety without substitution.
(ff) Amend Section 8.11.1.1.2(a) to read as follows: A qualified inspector shall attest to the Category 1, Category 3, and Category 5 Periodic Test Requirements. This qualified inspector shall sign an attestation for each test that reads, "I hereby attest under penalty for perjury that:
(A) all of the required tests have been completed by persons qualified to perform such services; and
(B) the regulated lifting device conforms to all applicable building and equipment codes in effect at the time of installation and all applicable building and equipment codes effective as applicable to and for each alteration.".
(gg) Amend Section 8.11.1.1.2(b) to read as follows: The owner or the owner's authorized agent shall have all of the tests required by 8.11.2, 8.11.3, 8.11.4, and 8.11.5 made by persons qualified to perform such service. For the Category 1, Category 3, and Category 5 Test Requirements, the owner or the owner's authorized agent shall have these tests attested to by a qualified inspector in the manner specified in 8.11.1.1.2(a).
(hh) Amend Section 8.11.1.3 to read as follows: The frequency of periodic inspections shall be established by the authority having jurisdiction and the frequency of periodic tests shall be as established in the Indiana Elevator Safety Code (675 IAC 21).
(ii) Delete Section 8.11.2.1, Periodic Inspection Requirements, in its entirety without substitution.
(jj) Delete Section 8.11.3.1, Periodic Inspection Requirements, in its entirety without substitution.
(kk) Amend Section 8.11.3.2.1 to read as follows: Relief Valve Setting and System Pressure Test. The relief valve setting shall be tested to determine that it will bypass the full output of the pump before the pressure exceeds 125% of the working pressure for elevators installed before January 3, 2003, and 150% of the working pressure for elevators that were installed after January 3, 2003, and that the system will withstand this pressure. It shall be sealed if the relief valve setting is altered or if the seal is broken.
(ll) Delete Section 8.11.4.1 in its entirety without substitution.
(mm) Delete Section 8.11.5.2 in its entirety without substitution.
(nn) Delete Section 8.11.5.13.1 in its entirety without substitution.
(oo) In Section 9, the following definitions are applicable:
(1) Except as specified in subdivision (2), "latest edition" means the edition that is in effect on November 1, 2006.
(2) For those codes that areadopted in this article, "latest edition" means the edition that has been adopted into this article.
(pp) Delete the following appendices without substitution:
(1) Appendix D.
(2) Appendix E.
(3) Appendix H.
(4) Appendix K.
(5) Appendix M.
(qq) Appendix N is adopted and amended as follows: In Table N1, delete without substitution, both columns under Periodic Inspections.
(rr) The following appendices areadopted:
(1) Appendix A.
(2) Appendix B.
(3) Appendix C.
(4) Appendix F.
(5) Appendix G.
(6) Appendix I.
(7) Appendix J.
(8) Appendix P.
(ss) Delete Appendix L and insert the following:

APPENDIX L

INDEX OF ALTERATION REQUIREMENTS FOR ELECTRIC ELEVATORS, HYDRAULIC ELEVATORS, ESCALATORS, AND MOVING WALKS

Item Electric Elevators Hydraulic Elevators Escalators and Moving Walks Permit Required
Access doors and openings 8.7.2.7.3 8.7.2.7.3 8.7.6.1.14, 8.7.6.2.14 New - Yes
Addition of elevator to existing hoistway 8.7.2.1.2 8.7.2.1.2 Yes
Ascending car overspeed and unintended movement 8.7.2.20 Yes
Capacity 8.7.2.16 Yes
Car door or gate 8.7.2.14 8.7.3.13 New - Yes
Car enclosure 8.7.2.14, 8.7.2.27.7 8.7.3.13 Replace or repair-No - New - Yes
Car frame and platform 8.7.2.15.1 8.7.3.14 Yes
Car and counterweight safeties 8.7.2.18 8.7.3.15 Yes
Carrying of passengers on freight elevators 8.7.2.16.3 8.7.3.19 Yes
Change in class of loading 8.7.2.16.2 8.7.3.18 Yes
Change in location of hydraulic jack 8.7.3.23.5 Yes
Change in power supply 8.7.2.27.3 8.7.3.31.4 Yes
Change in ropes 8.7.2.21.1 8.7.3.25.1 Yes
Change in type of motion control 8.7.2.27.6 8.7.3.31.7 Yes
Change in type of operation control 8.7.2.27.6 8.7.3.31.7 Yes
Change in type of service 8.7.2.16.1 8.7.3.17 Yes
Construction at bottom of hoistway 8.7.2.1.4 8.7.2.1.4 Yes
Construction at top of hoistway 8.7.2.1.3 8.7.2.1.3 Yes
Controller 8.7.2.27.4 8.7.3.31.5 Yes
Counterweight, location and guarding of 8.7.2.3 8.7.3.3 Yes
Cylinder 8.7.3.23.3 Yes
Driving machine 8.7.2.25.1 8.7.3.23 Yes
Driving machine, change in location of 8.7.2.25.2 8.7.3.23.4 Yes
Egress, escalator 8.7.6.1.15 Yes
Electrical equipment, wiring, pipes, ducts in HW. & 8.7.2.8 8.7.3.8 Yes
M.R.
Emergency operations 8.7.2.28 8.7.3.31.8 Yes
Entrance and egress escalator and moving walk 8.7.6.1.15 Yes
Entrance, horizontal slide type 8.7.2.10.2 8.7.2.10.2 Yes
Entrance, swing type 8.7.2.10.4 8.7.2.10.4 Yes
Entrance, vertical slide type 8.7.2.10.3 8.7.2.10.3 Yes
Emergency door 8.7.2.10.1 8.7.3.10 Yes
General requirements, escalators and moving walks 8.7.6.1.1, 8.7.6.2.1 Yes
Hand elevators 8.7.4.3 Yes
Hoistway enclosure 8.7.2.1 8.7.3.1 Yes
Inclined elevators 8.7.5.1 8.7.5.1 Yes
Increase in deadweight of car 8.7.2.15.2 8.7.3.21 Less than 5% - No 5% or More - Yes
Increase in rated load 8.7.2.16.4 8.7.3.20 Yes
Increase in rated speed 8.7.2.17.2 8.7.3.22.2 Yes
Increase in travel 8.7.2.17.1 8.7.3.22.1 Yes
Increase in working pressure 8.7.3.23.4 Less than 5% - No 5% or More - Yes
Jack, hydraulic 8.7.2.7.1 8.7.3.23 Yes
Machine room and machinery spaces 8.7.2.9 8.7.3.7 Yes
Machinery and sheave beams, supports and 8.7.7.3 8.7.3.9 Yes
foundations
Material lift with automatic transfer device 8.7.2.11.2 8.7.7.3 Yes
Operating and safety device 8.7.3.23.2 Yes
Plunger 8.7.3.23.2 Yes
Plunger gripper 8.7.3.23.7 Yes
Protection of truss and machinery spaces against 8.7.6.1.4, Yes
fire 8.7.6.2.4
Rack and pinion 8.7.4.1 Yes
Rated load and speed 8.7.6.1.11, 8.7.6.2.11 Yes
Relocation of escalator 8.7.6.1.2 Yes
Relocation of hydraulic machine 8.7.3.23.6 Yes
Relocation of moving walk 8.7.6.2.2 Yes
Roof top elevators 8.7.5.6 8.7.5.6 Yes
Screw column elevators 8.7.4.2 Yes
Sidewalk elevators 8.7.5.5 8.7.5.5 Yes
Signaling devices 8.7.2.28 Yes
Special purpose elevators 8.7.5.7 8.7.3.31.8 Yes
Step system 8.7.6.1.7 Yes
Track system 8.7.6.1.10, 8.7.6.2.10 Yes
Treadway system 8.7.6.2.7 Yes
Trusses and girders 8.7.6.1.9, 8.7.6.2.9 Yes

675 IAC 21-3-2

Fire Prevention and Building Safety Commission; 675 IAC 21-3-2; filed Aug 30, 1985, 11:52 a.m.: 9 IR 41, eff Oct 1, 1985; filed Nov 14, 1986, 9:22 a.m.: 10 IR 873, eff Jan 1, 1987; filed Sep 27, 1989, 4:30 p.m.: 13 IR 288; filed Feb 23, 1995, 11:00 a.m.: 18 IR 1832; readopted filed Sep 11, 2001, 2:49 p.m.: 25 IR 530; filed Dec 3, 2002, 3:05 p.m.: 26 IR 1087; filed Nov 16, 2006, 4:04 p.m.: 20061213-IR-675050050FRA; filed Mar 14, 2011, 10:22 a.m.: 20110413-IR-675090871FRA; readopted filed Aug 8, 2012, 8:08 a.m.: 20120905-IR-675120260RFA
Readopted filed 7/3/2018, 2:22 p.m.: 20180801-IR-675180204RFA