Section 675 IAC 20-3-4 - DecksAuthority: IC 22-13-2-2
Affected: IC 22-12; IC 22-13; IC 22-15; IC 36-7
Sec. 4.
(a) A deck not less than four (4) feet in width shall surround not less than fifty percent (50%) of the perimeter of a spa.(b) Decks shall meet the following requirements:(1) Surfaces shall be slip-resistant but not providing an abrasion hazard.(2) The maximum dimension of any horizontal void shall be three-sixteenths (3/16) of an inch, and the maximum vertical difference in surfaces other than stairs shall be one-fourth (1/4) of an inch.(3) All corners shall be rounded or relieved.(4) Decks shall drain away from the spa.Fire Prevention and Building Safety Commission; 675 IAC 20-3-4; filed Aug 14, 1989, 9:00 a.m.: 13 IR 60, eff Sep 1, 1989 [IC 4-22-2-36 suspends the effectiveness of a rule document for thirty 30 days after filing with the secretary of state. LSA Document #89-17 was filed Aug 14, 1989.]; readopted filed Sep 11, 2001, 2:49 p.m.: 25 IR 530; readopted filed Sep 21, 2007, 9:20 a.m.: 20071010-IR-675070388RFA; readopted filed Oct 10, 2007, 9:16 a.m: 20071031-IR-675070388RFA; readopted filed Aug 7, 2013, 8:51 a.m.: 20130904-IR-675130181RFAReadopted filed 7/2/2019, 2:21 p.m.: 20190731-IR-675190264RFA