Current through November 6, 2024
Section 410 IAC 7-24-377 - Direct connection, prohibitedAuthority: IC 16-42-5-5
Affected: IC 16-42-5
Sec. 377.
(a) Except as specified in this section, a direct connection may not exist between the sewage system and a drain originating from equipment in which food, portable equipment, or utensils are placed.(b) If allowed under the Indiana plumbing code, a warewashing machine may have a direct connection between its waste outlet and a floor drain when the:(1) machine is located within five (5) feet of a trapped floor drain; and(2) machine outlet is connected to the inlet side of a properly vented floor drain trap.(c) If allowed by law, a warewashing or culinary sink may have a direct connection.(d) For purposes of this section, a violation of subsection (a), (b), or (c) is a critical item.Indiana State Department of Health; 410 IAC 7-24-377; filed Oct 13, 2004, 12:30 p.m.: 28 IR 893; readopted filed Jul 15, 2010, 12:12 p.m.: 20100728-IR-410100261RFAReadopted filed 11/10/2016, 8:45 a.m.: 20161207-IR-410160371RFAReadopted filed 9/15/2022, 10:01 a.m.: 20221012-IR-410220206RFA