Current through November 6, 2024
Section 410 IAC 7-24-282 - Warewashing machine; flow pressure deviceAuthority: IC 16-42-5-5
Affected: IC 16-42-5
Sec. 282.
(a) Warewashing machines that provide a fresh hot water sanitizing rinse shall be equipped with a pressure gauge or similar device, such as a transducer, that measures and displays the water pressure in the supply line immediately before entering the warewashing machine.(b) If the flow pressure measuring device is upstream of the fresh hot water sanitizing rinse control valve, the device shall be mounted in a one-fourth (1/4) inch iron pipe size (IPS) valve.(c) Subsections (a) and (b) do not apply to a machine that uses only a pumped or recirculated sanitizing rinse.(d) For purposes of this section, a violation of subsection (a), (b), or (c) is a noncritical item.Indiana State Department of Health; 410 IAC 7-24-282; filed Oct 13, 2004, 12:30 p.m.: 28 IR 876; readopted filed Jul 15, 2010, 12:12 p.m.: 20100728-IR-410100261RFAReadopted filed 11/10/2016, 8:45 a.m.: 20161207-IR-410160371RFAReadopted filed 9/15/2022, 10:01 a.m.: 20221012-IR-410220206RFA