410 Ind. Admin. Code 6-7.1-25

Current through November 6, 2024
Section 410 IAC 6-7.1-25 - Sanitary dumping station

Authority: IC 16-19-3-4

Affected: IC 16-19-3

Sec. 25.

(a) All campgrounds, except those having only independent campsites, shall have at least one (1) sanitary dumping station for each two hundred fifty (250) dependent campsites or fraction thereof.
(b) Each sanitary dumping station must be equipped with the following:
(1) A four (4) inch sewer riser pipe with a self-closing hinged cover or other tight-fitting closure.
(2) A concrete apron at least three (3) feet in diameter and sloped to drain the area surrounding the inlet of the riser pipe.
(3) A water outlet for sanitary maintenance of the station.
(4) A sign located at the water outlet which states that the water is not for drinking, but for flushing and cleaning holding tanks and the dump station area.
(5) A vacuum breaker installed downstream of the last shut-off valve that meets the requirements of 675 IAC 16.
(c) Sanitary dumping stations shall be capable of receiving a sewage flow of at least twenty (20) gallons per day for each dependent campsite served.
(d) Sanitary dumping stations utilizing holding tanks shall be capable of receiving a sewage flow of at least sixty (60) gallons per day for each dependent campsite served.

410 IAC 6-7.1-25

Indiana State Department of Health; 410 IAC 6-7.1-25; filed Jun 27, 2002, 1:30 p.m.: 25 IR 3746; readopted filed Jul 14, 2008, 2:14 p.m.: 20080806-IR-410080322RFA
Readopted filed 9/10/2014, 2:08 p.m.: 20141008-IR-410140299RFA
Readopted filed 9/10/2020, 2:11 p.m.: 20201007-IR-410200404RFA