410 Ind. Admin. Code 6-14-19

Current through November 6, 2024
Section 410 IAC 6-14-19 - Electrical facilities

Authority: IC 16-19-3-4.4

Affected: IC 8-9-10; IC 16-19-3

Sec. 19.

(a) All camp car electrical:
(1) wiring;
(2) switches; and
(3) lighting fixtures;

shall be installed and maintained in a safe condition.

(b) Electrical receptacles shall have wiring and circuit breakers or fuses sized to conform to the amperage of the receptacle they supply.
(c) When located in wet places or outside a camp car, the following shall be weatherproof:
(1) Electrical switches.
(2) Circuit breakers.
(3) Receptacles.
(4) Control equipment.
(5) Metering devices.
(d) Electrical receptacles shall:
(1) be grounded; and
(2) not have an open neutral, open hot conductor, or reverse polarity.
(e) Splices in electrical wires in accessible locations shall be made using approved junction boxes.
(f) All light fixtures shall be covered or shielded to protect against injury resulting from bulb breakage.
(g) All electrical receptacles and switches shall be shielded to prevent electric shock.
(h) Unshielded bare electrical wires:
(1) are prohibited; and
(2) shall be wrapped or otherwise covered to prevent electric shock.
(i) All restrooms and shower/locker room electrical receptacles provided for connection of personal grooming equipment shall be protected by ground fault circuit interrupters to prevent electric shock.

410 IAC 6-14-19

Indiana State Department of Health; 410 IAC 6-14-19; filed Oct 30, 2008, 4:02 p.m.: 20081126-IR-410070490FRA
Readopted filed 9/10/2014, 2:08 p.m.: 20141008-IR-410140299RFA
Readopted filed 9/10/2020, 2:11 p.m.: 20201007-IR-410200404RFA