Current through January 8, 2025
Section 355 IAC 3-8-4 - Shutoff valves; check valvesAuthority: IC 15-16-1-6; IC 15-16-1-7
Affected: IC 15-16-1-10; IC 15-16-1-11
Sec. 4.
(a) Shutoff valves shall be:(1) provided for all connections, except those with a No. 54 drill size restriction, plugs, safety valves, and thermometer wells; and(2) located as close to the tank as practicable.(b) When operating conditions make it advisable, a check valve shall be installed on the fill connection and a remotely operated shutoff valve on other connections located below the maximum liquid level. State Chemist of the State of Indiana; Agricultural Ammonia PT A, Sec VIII, Rule 8.3; filed Dec 30, 1965, 2:15 p.m.: Rules and Regs. 1966, p. 21; filed Jan 19, 2001, 2:04 p.m.: 24 IR 1645; readopted filed Jun 20, 2001, 3:22 p.m.: 24 IR 3822; readopted filed Apr 27, 2007, 2:03 p.m.: 20070509-IR-355070039RFA; readopted filed November 25, 2013, 3:27 p.m.: 20131225-IR-355130482RFAReadopted filed 7/2/2019, 10:42 a.m.: 20190731-IR-355190258RFA