329 Ind. Admin. Code 11.7-6-1

Current through November 6, 2024
Section 329 IAC 11.7-6-1 - Operational requirements

Authority: IC 13-14-8-7; IC 13-15; IC 13-19-3

Affected: IC 13-30-2; IC 36-9-30

Sec. 1.

(a) A facility that processes or stores alternative fuel or residue must have the following:
(1) An appropriate surface or pad for processing, such as concrete or asphalt, that will control spills and any liquids or leachate. Examples of an appropriate surface would be concrete or asphalt. Facilities that are registered under this article that are only processing uncontaminated wood or plastic are not required to process on a pad.
(2) Adequate measures in place to control fire hazards, and equipment available to control fires. The contingency action plan required under 329 IAC 11.7-4-1(f)(13) must be submitted to the local fire department that services the area.
(3) A telephone, cellular telephone, or radio communication device available when employees are present and the building is in use.
(4) Access control to the facility.
(5) A sign at least one (1) foot high by two (2) feet wide prominently displayed by the door or entrance to the facility and legibly containing the following information:
(A) The name of the facility.
(B) The IDEM registration number.
(C) The name and phone number of a designated emergency contact person.
(6) Adequate control of the following:
(A) Dust.
(B) Odors.
(C) Wastewater.
(D) Vectors.
(E) Litter.
(F) Leachate.
(7) Monitoring of incoming alternative fuels. Any waste that the facility is not registered or permitted to receive for processing must be isolated and removed from the facility.
(b) The owner or operator shall record and retain at the registered facility, or in an alternative location approved by the commissioner, all records, reports, or audits required by this article until certification of closure is deemed adequate by the commissioner under 329 IAC 11.7-8-1(e). The following information must be retained:
(1) A paper copy or an accessible copy of the electronically submitted registration submission.
(2) A contingency action plan as required under 329 IAC 11.7-4-1(f)(13).
(3) The records required under 329 IAC 11.7-5-1(b)(2).
(4) The training log required under subsection (f).
(5) The results of any waste determination tests on the residues generated by the registered facility.
(c) The following must be furnished as required and made available during normal operating hours for inspection by any officer, employee, or representative of the commissioner:
(1) All records required by this article.
(2) All test results of the alternative fuels received and residues generated by the registered facility and disposed.
(d) No hazardous waste that is regulated by 329 IAC 3.1 shall be processed at any registered facility, unless the facility is permitted under 329 IAC 3.1 to process hazardous waste.
(e) Employees must be trained on safety, emergency, and operational procedures for the facility. A training log must be kept at the registered facility for five (5) years stating the following:
(1) The name of the employee.
(2) Training topics.
(3) Hours of training.

329 IAC 11.7-6-1

Solid Waste Management Division; 329 IAC 11.7-6-1; filed Jan 30, 2013, 12:35 p.m.: 20130227-IR-329090194FRA