Sec. 3.
Agricultural lime substitute must be evenly applied at rates based on the adjusted lime rate as determined by Equation 4 as follows:
Equation 4:
Adjusted Lime Rate = RALR × FF × NF × DF
Where: RALR = Recommended agricultural lime rate derived from the soil analysis report for the application site.
FF = Fineness factor.
NF = Neutralizing factor.
DF = Depth factor.
Table 7 Fineness Factor
Mesh Size | Percent 8 | Passing 20 | Mesh 60 | Size 100 | Fineness Factor (FF) |
100 | 100 | 100 | 100 | .60 | |
100 | 100 | 95 | 80 | .63 | |
100 | 95 | 70 | 60 | .76 | |
95 | 70 | 50 | 40 | 1.00 | |
85 | 60 | 40 | 30 | 1.19 | |
80 | 50 | 30 | 20 | 1.45 | |
80 | 45 | 20 | 10 | 1.77 | |
80 | 40 | 15 | 5 | 2.03 |
Table 8 Neutralizing Factor
CCE* | Neutralizing Factor (NF) |
110-119 | .83 |
100-109 | .90 |
90-99 | 1.00 |
80-89 | 1.12 |
70-79 | 1.27 |
60-69 | 1.46 |
50-59 | 1.73 |
40-49 | 2.00 |
*CCE = Calcium Carbonate Equivalency
Table 9 Depth Factor
Plowing Depth (Inches) | Depth Factor (DF) |
0-<=4 | .50 |
>4-<=6 | .75 |
>6-<=8 | 1.00 |
>8-<=10 | 1.25 |
>10-<=12 | 1.50 |
327 IAC 6.1-6-3