326 Ind. Admin. Code 6.5-5-2

Current through May 29, 2024
Section 326 IAC 6.5-5-2 - FCA US, LLC - Kokomo Casting Plant and Kokomo Transmission Plant

Authority: IC 13-14-8; IC 13-17-1-1; IC 13-17-3-4; IC 13-17-3-14

Affected: IC 13-15; IC 13-17

Sec. 2.

(a)FCA US, LLC - Kokomo Casting Plant in Howard County shall meet the following emission limits:

SourceSource ID No.Point Input IDProcessEmission Limits
tons/yrgrains/dscf
FCA US, LLC - Kokomo00065
Casting Plant
4PReverberatory Furnace 2RF92.50.85
8PReverberatory Furnace 6RF36.20.63
9PGas Boiler 2

(b) Boiler 4 at the FCA US, LLC - Kokomo Transmission Plant, source identification number 00078, shall burn reclaimed residual oil or natural gas and shall meet a particulate matter emission limit of 0.75 lb/MMBtu. Boiler 5 at this facility shall burn natural gas only.

326 IAC 6.5-5-2

Air Pollution Control Board; 326 IAC 6.5-5-2; filed Aug 10, 2005, 1:00 p.m.: 28 IR 3468; filed Jan 23, 2008, 1:44 p.m.: 20080220-IR-326040279FRA
Filed 4/29/2015, 3:35 p.m.: 20150527-IR-326120520FRA