Where: t = Calculated t value.
d = Average difference between paired data.
Sd = Standard deviation of the differences.
N = Number of paired data sets.
The calculated t value is compared to the t value in the standard statistical t tables at the ninety-five percent (95%) probability and the appropriate degrees of freedom (n - 1). If the calculated t value is greater than or equal to the value of t in the t table, then the systems are not comparable. Certain coals with low variability may detect a small bias, which may be acceptable as decided on a case-by-case basis. This method tests for positive and negative bias. Provisions for testing only for a negative bias that would cause a source owner or operator to report less than actual values may be acceptable if supported by statistical tests. Upon request, the department shall provide written guidance to a source owner or operator as to the procedures to be followed in conducting this comparison.
the department may notify the owner or operator that the demonstration shall be repeated. Written notification by the department of the request shall be made to the source owner or operator allowing at least sixty (60) days to schedule the demonstration.