Table E - Drainage Fixture Units (D.F.U.) Per Fixture Group

Type of Fixture

D.F.U./Fixture (Load)

Minimum Size of Trap2 (inches)

Bathroom groups:

1 tank water closet, 1 lavatory

with 1¼ inch trap and 1

bathtub1 or shower stall

7

11/4

1 water closet with flush valve, 1

lavatory with 1¼ inch trap and 1

bathtub or shower1

11

Bathtub (with or without overhead shower)1

2

Bathtub1

3

2

Bidet

2

Clothes washer, automatic

3

2

Dental unit or cuspidor

1

Drinking fountain

½

1

Dishwasher2, domestic

2

Floor drains

See Appendix A, Table F

2

Lavatories:

Lavatory

1

Lavatory

2

Lavatory, barber, beauty parlor

2

Lavatory, dental

1

Lavatory, surgeon's

2

Laundry tray (1 or 2 compartments)

2

Type of Fixture

D.F.U./Fixture (Load)

Minimum Size of Trap2 (inches)

Shower stall

3

2

Showers (group) per head2

3

2

Sinks:

Combination sink and tray

3

Combination sink and tray with

food-disposal unit

4 Separate Traps

Flushing rim (with valve)

8

3

Kitchen sink, domestic

2

Kitchen sink, domestic, with food-waste

grinder

3 Separate Traps

Pot, scullery, etc.2

4

Service (P trap)

3

3

Service (P trap)

2

2

Surgeon's

3

Wash sink2 (circular or multiple),

each set of faucets

2

Urinals:

Urinal, pedestal, siphon jet, blowout

8

2

Urinal stall

3

2

Urinal, wall integral trap

3

2

Urinal, wall P trap, exposed

2

Water closets:

Tank operated

4

3

Valve-operated

8

3

1A shower head over a bathtub does not increase the fixture value.

2See Appendix A: Table F and Section 890.1330(b) for method of determining unit values of fixtures not listed in this Table or for rating of devices with intermittent flows.

Ill. Admin. Code tit. 77, 890, Subpart M, Appendix A E

Amended at 28 Ill. Reg. 4215, effective February 18, 2004