Ill. Admin. Code tit. 35 § 901.103

Current through Register Vol. 48, No. 25, June 21, 2024
Section 901.103 - Sound Emitted to Class B Land

Except as provided elsewhere in this Part, a person must not cause or allow the emission of sound from any property-line noise source located on any Class A, B or C land to any receiving Class B land that exceeds any allowable octave band sound pressure level specified in the following table, when measured at any point within the receiving Class B land. Sound pressure levels must be measured at least 25 feet from the property-line noise source.

Octave Band Center Frequency (Hertz)

Allowable Octave Band Sound Pressure Levels (dB) of Sound Emitted to any Receiving Class B Land from

Class C Land

Class B Land

Class A Land

31.5

80

79

72

63

79

78

71

125

74

72

65

250

69

64

57

500

63

58

51

1000

57

52

45

2000

52

46

39

4000

48

41

34

8000

45

39

32

Ill. Admin. Code tit. 35, § 901.103

Amended at 30 Ill. Reg. 5533, effective March 10, 2006