WQS = [(Qe)(PEL) + (Qd)(Cd)]/(Qe + Qd)
or
PEL = [WQS(Qe + Qd) - (Qd)(Cd)]/Qe
where:
WQS | = | applicable total ammonia nitrogen water quality standard pursuant to Section 355.203 |
Qe | = | effluent flow rate |
Qd | = | allowed mixing flow rate as determined in accordance with the provisions of 35 Ill. Adm. Code 302.212(c) |
Cd | = | background ammonia nitrogen (as N) concentration in mixing water |
Effluent flow rate shall be selected to coincide with the critical stream flow condition used to quantify allowed dilution. Typically this will be estimated to be the average of the lowest three months average flow rate during the previous year for domestic wastewater sources. For industrial and other wastewater sources where flow rates are not directly correlated to climatic patterns, Qe will be estimated as the average of the highest three monthly average flow rates. With either approach, Qe shall be modified when future flows are expected to vary significantly from historical data.
Ill. Admin. Code tit. 35, § 355.209
Amended at 27 Ill. Reg. 15774, effective September 25, 2003