Current through Register Vol. 48, No. 44, November 1, 2024
Section 276.606 - On-Road Remote Sensing Test Systems Maintenance and Calibrationa) All equipment utilized for on-road remote sensing emission measurement shall be maintained and calibrated according to the manufacturer's specifications.b) The accuracy of the Infrared SDM shall be verified by measuring the concentration of tri-blend (CO2, HC, CO) calibration gas released from a specially modified vehicle. A two point gas calibration procedure shall be followed. The span shall be accomplished at the following pair of span points: 300 - ppm propane (HC)
1.0 - percent CO
6.0 - percent CO2
1200 - ppm propane (HC)
4.0 - percent CO
12.0 - percent CO2
The Infrared SDM shall measure the span gas within the allowable tolerance range specified in Section 276.507(b) of this Part.
Ill. Admin. Code tit. 35, § 276.606