An "X" in any box in this matrix means that measurement of that parameter is required.
MINIMUM FREQUENCY | CONTROL SYSTEM | ||||||
Operating Parameters | Data Measurement | Data Recording | Dry Scrubber Followed by Fabric Filter | Wet Scrubber | Dry Scrubber Followed by Fabric Filter and Wet Scrubber | Selective Noncatalytic Reduction System | |
Maximum Charge Rate1 | Continuous | Once per hour | X | X | X | X | |
Maximum Fabric Filter Inlet Temperature | Continuous | Once per minute | X | X | |||
Maximum Flue Gas Temperature | Continuous | Once per minute | X | X | |||
Minimum Secondary Chamber Temperature | Continuous | Once per minute | X | X | X | X | |
Minimum Dioxin/Furan Sorbent Flow Rate | Hourly | Once per hour | X | X | |||
Minimum HCl Sorbent Flow Rate | Hourly | Once per hour | X | X | |||
Minimum Reagent Flow Rate | Hourly | Once per hour | X | ||||
Minimum Hg Sorbent Flow Rate | Hourly | Once per hour | X | X | |||
Minimum Pressure Drop Across the Wet Scrubber or Minimum Horsepower or Amperage to Wet Scrubber | Continuous | Once per minute | X | X | |||
Minimum Scrubber Liquor Flow Rate | Continuous | Once per hour | X | X | |||
Minimum Scrubber Liquor pH | Continuous | Once per hour | X | X |
1For batch HMIWIs, record the charge per batch.
Ill. Admin. Code tit. 35, pt. 229, subpt. L, app B