where:
Ep | = | Total maximum theoretical emissions of VOM from one heatset web offset printing line in units of kg/yr (lb/yr); |
A | = | Weight of VOM per volume of solids of ink with the highest VOM content as applied each year on the printing line in units of kg/l (lb/gal) of solids; |
B | = | Total volume of solids for all inks that can potentially be applied each year on the printing line in units of 1/yr (gal/yr). The method by which the owner or operator accurately calculated the volume of each ink as applied and the amount that can potentially be applied each year on the printing line shall be described in the certification to the Agency; |
C | = | Weight of VOM per volume of fountain solution with the highest VOM content as applied each year on the printing line in units of kg/l (lb/gal); |
D | = | The total volume of fountain solution that can potentially be used each year on the printing line in units of 1/yr (gal/yr). The method by which the owner or operator accurately calculated the volume of each fountain solution used and the amount that can potentially be used each year on the printing line shall be described in the certification to the Agency; |
F | = | Weight of VOM per volume of material for the cleanup material or solvent with the highest VOM content as used each year on the printing line in units of kg/l (lb/gal) of such material; |
G | = | The greatest volume of cleanup material or solvent used in any 8-hour period; |
H | = | The highest fraction of cleanup material or solvent that is not recycled or recovered for offsite disposal during any 8-hour period; |
R | = | The multiplier representing the amount of VOM not retained in the substrate being used. For paper, R = 0.8. For metal, plastic, or other impervious substrates, R = 1.0; |
where:
VOMtot | = | Total VOM in the fountain solution; |
VOMfs | = | VOM emitted from the fountain solution; |
DE | = | Destruction efficiency of the control device on the associated dryer, in decimal form (i.e., 95% control is represented as 0.95). If no control device is present, DE = 0; |
where:
VOMtot | = | Total VOM in the blanket wash; |
VOMtow | = | VOM emitted from the blanket wash; |
DE | = | Destruction efficiency of the control device on the associated dryer, in decimal form (i.e., 95% control is represented as 0.95). If no control device is present, DE = 0; |
Ill. Admin. Code tit. 35, § 218.411
Amended at 35 Ill. Reg. 13473, effective July 27, 2011