The following test methods and procedures shall be used to determine compliance of as applied coatings, inks, and fountain solutions with the limitations set forth in this Part.
The requirements of subsection (c)(2) of this Section shall apply to all VOM emitting process emission units employing capture equipment (e.g., hoods, ducts), except those cases noted in this subsection (c)(1).
The capture efficiency of an emission unit shall be measured using one of the protocols given below. Appropriate test methods to be utilized in each of the capture efficiency protocols are described in appendix M of 40 CFR 51, incorporated by reference at Section 218.112 of this Part. Any error margin associated with a test method or protocol may not be incorporated into the results of a capture efficiency test. If these techniques are not suitable for a particular process, then an alternative capture efficiency protocol may be used, pursuant to the provisions of Section 218.108(b) of this Part.
where:
CE | = | Capture efficiency, decimal fraction; |
Gw | = | Mass of VOM captured and delivered to control device using a TTE; |
Fw | = | Mass of uncaptured VOM that escapes from a TTE. |
Method 204B or 204C contained in appendix M of 40 CFR 51, incorporated by reference in Section 218.112 of this Part, is used to obtain Gw. Method 204D in appendix M of 40 CFR 51, incorporated by reference in Section 218.112 of this Part, is used to obtain Fw.
where:
CE | = | Capture efficiency, decimal fraction; |
L | = | Mass of liquid VOM input to process emission unit; |
Fw | = | Mass of uncaptured VOM that escapes from a TTE. |
Method 204A or 204F contained in appendix M of 40 CFR 51, incorporated by reference in Section 218.112 of this Part, is used to obtain L. Method 204 D in appendix M of 40 CFR 51, incorporated by reference in Section 218.112 of this Part, is used to obtain Fw.
where:
CE | = | Capture efficiency, decimal fraction; |
G | = | Mass of VOM captured and delivered to control device; |
FB | = | Mass of uncaptured VOM that escapes from building enclosure. |
Method 204B or 204C contained in appendix M of 40 CFR 51, incorporated by reference in Section 218.112 of this Part is used to obtain G. Method 204E in appendix M of 40 CFR 51, incorporated by reference in Section 218.112 of this Part is used to obtain FB.
where:
CE | = | Capture efficiency, decimal fraction; |
L | = | Mass of liquid VOM input to process emission unit; |
FB | = | Mass of uncaptured VOM that escapes from building enclosure. |
Method 204A or 204F contained in appendix M of 40 CFR 51, incorporated by reference in Section 218.112 of this Part is used to obtain L. Method 204E in appendix M of 40 CFR 51, incorporated by reference in Section 218.112 of this Part is used to obtain FB.
BOARD NOTE: Where LCL was used in testing emission units that are the subject of later requests for establishing emission credits for offsets, shutdowns, and trading, prior LCL results may not be relied upon to determine the appropriate amount of credits. Instead, to establish the appropriate amount of credits, additional testing may be required that would satisfy the protocol of Section 218.105(c)(2)(A), (B), (C) or (D), the DQO protocol of Section 218.105(c)(2)(E), or an alternative protocol pursuant to Section 218.108(b) of this Part.
where:
E | = | Equivalent overall efficiency of the capture system and control device as a percentage; |
VOMa | = | Actual VOM content of a coating, or the daily-weighted average VOM content of two or more coatings (if more than one coating is used), as applied to the subject coating line as determined by the applicable test methods and procedures specified in subsection (a) of this Section in units of kg VOM/1 (lb VOM/gal) of coating solids as applied; |
VOMl | = | The VOM emission limit specified in Section 218.204 or 218.205 of this Part in units of kg VOM/l (lb VOM/gal) of coating solids as applied. |
The methods in 40 CFR 60, appendix A, incorporated by reference in Section 218.112 of this Part delineated below shall be used to determine control device efficiencies.
Owners or operators required by this Part to carry out a leak detection monitoring program shall comply with the following requirements:
The methods for determining the acceptable performance of Stage II Gasoline Vapor Recovery System are delineated in "Technical Guidance-Stage II Vapor Recovery Systems for Control of Vehicle Refueling Emissions at Gasoline Dispensing Facilities," found at EPA 450/3-91-022b and incorporated by reference in Section 218.112 of this Part. Specifically, the test methods are as follows:
Ill. Admin. Code tit. 35, § 218.105
Amended at 35 Ill. Reg. 13473, effective July 27, 2011