Idaho Admin. Code r. 24.39.40.012

Current through September 2, 2024
Section 24.39.40.012 - APPROVAL OF NEW OR ALTERNATIVE TECHNOLOGY
01.Administrator Approval Required. If, due to construction or technological impediments, an elevator or conveyance cannot comply with applicable code requirements, approval of new or alternative construction or technology may be requested from the administrator. Approval must be obtained before commencement of construction.
02.Submission Deadline. Details of the proposed construction or technology, including design, material specifications and calculations, and such other information as may be requested, must be submitted to the administrator at least thirty (30) days in advance of the anticipated construction start date.
a. The manufacturer of the new product or system must provide the administrator with an Accredited Elevator/Escalator Certification Organization (AECO) approval and certification in accordance with ANSI/ASME A17.7 Performance-based Safety Code for Elevators and Escalators or engineering and test data demonstrating that the proposed technology is safe for the intended purpose.
b. The owner of the new product or system must provide the administrator with a document in which the owner acknowledges that the proposed technology is not governed by the applicable safety code and assures the administrator that, at such time as the code is revised to include the product or system, the owner will modify the product or system to bring it into compliance. The owner must assure the administrator that if the product or system cannot be modified or altered to bring it into compliance with the applicable code it will be removed and replaced with code-compliant equipment.
c. The manufacturer of the new product or system must provide training to Division personnel on the proposed technology and any related products or systems at no cost to the Division.
03.Engineer Approval. The information provided in compliance with the foregoing requirements must be approved by an Accredited Elevator/Escalator Certification Organization (AECO) or a registered professional engineer experienced in elevator or conveyance design prior to submission to the administrator.

Idaho Admin. Code r. 24.39.40.012

Effective March 28, 2023