Idaho Admin. Code r. 16.02.14.281

Current through August 31, 2023
Section 16.02.14.281 - OVERFLOW GUTTERS

The gutter, drains, and return piping to the surge system must be designed to rapidly remove overflow water caused by recirculation displacement, wave action, or other causes produced from the maximum pool bathing load. (3-15-22)

01.General Requirements. Overflow gutters must: (3-15-22)
a. Extend around the entire perimeter of the pool except at steps or recessed ladders; (3-15-22)
b. Have the gutter lip be level within three-tenths (.3) inch; (3-15-22)
c. Be capable of continuously removing fifty percent (50%) of the recirculated water and returning it to the recirculation system; and (3-15-22)
d. Be designed to prevent entrance or entrapment of bathers. (3-15-22)
02.Overflow Gutters Connected to the Recirculation System. All overflow gutters connected to the recirculation system must be connected in an approved manner, such as a surge tank. (3-15-22)

Idaho Admin. Code r. 16.02.14.281