Idaho Admin. Code r. 16.02.14.270

Current through August 31, 2023
Section 16.02.14.270 - WALL INLETS
01.General Inlet Requirements. Except as otherwise provided in this rule, inlets must: (3-15-22)
a. Be rounded and smooth and installed not less than eighteen (18) inches below the normal operating level and located to produce a uniform circulation, without the existence of dead spots; and (3-15-22)
b. Not extend from the pool wall or floor so as to create a hazard. (3-15-22)
02.Wall Inlet Requirements. If wall inlets are used, there must: (3-15-22)
a. Be at a minimum of one (1) per each six hundred (600) square feet of pool surface area. (3-15-22)
b. Be a minimum of two (2) inlets. In case of a shallow pool, the Director's designee may grant an exception to this requirement if inlets cannot be installed at the depth otherwise required. (3-15-22)

Idaho Admin. Code r. 16.02.14.270