Idaho Admin. Code r. 16.02.14.270

Current through September 2, 2024
Section 16.02.14.270 - WALL INLETS
01.General Inlet Requirements. Except as otherwise provided in this rule, inlets must:
a. Be rounded and smooth and installed not less than eighteen (18) inches below the normal operating level and located to produce a uniform circulation, without the existence of dead spots; and
b. Not extend from the pool wall or floor so as to create a hazard.
02.Wall Inlet Requirements. If wall inlets are used, there must:
a. Be at a minimum of one (1) per each six hundred (600) square feet of pool surface area.
b. Be a minimum of two (2) inlets. In case of a shallow pool, the Director's designee may grant an exception to this requirement if inlets cannot be installed at the depth otherwise required.

Idaho Admin. Code r. 16.02.14.270

Effective March 15, 2022