Section R407 is added to the IECC to read as follows:
SECTION R407
POINTS OPTION
R407.1 General (Prescriptive). Above-grade walls and roof/ceiling assemblies are permitted to comply with the points option as an alternative to complying with Section R401.2.l and R402.2.
R407.2 Requirements. One or more efficiency measures shall be selected for roof/ceiling and above-grade wall systems from Table R407.l that cumulatively equal or exceed 0 (zero) points.
As an alternative, above-grade walls and roof/ceilings are permitted to comply separately by scoring 0 (zero) or greater.
TABLE R407.1
POINTS OPTION
Walls | Standard Home Points | Tropical Home Points | |
Wood Framed | |||
R-13 Cavity Wall Insulation | 0 | 1 | |
R-19 Roof/ceiling Insulation | -1 | 0 | |
R-19 Roof/ceiling Insulation + Cool roof membrane or Radiant Barrier3 | 0 | 1 | |
R-19 Roof/ceiling Insulation + Attic Venting2 | 0 | 1 | |
R-30 Roof/ceiling Insulation | 0 | 1 | |
R-13 Wall Insulation + high reflectance walls4 | 1 | 2 | |
R-13 Wall insulation + 90% high efficacy lighting and Energy Star Appliances5 | 1 | 2 | |
R-13 Wall Insulation + exterior shading wpf=O 36 | 1 | 2 | |
Ductless Air Conditioner | 1 | 1 | |
1.071 X Federal Minimum SEER for Air Conditioner | 1 | 1 | |
1.142 X Federal Minimum SEER for Air Conditioner | 2 | 2 | |
No air conditioning installed | Not Applicable | 2 | |
House floor area = 1,000 ft2 | 1 | 1 | |
House floor area = 2,500 ft2 | -1 | -1 | |
Energy Star Fans8 | 1 | 1 | |
Install 1 kW or greater of solar electric | 1 | 1 | |
Metal Framed | |||
R-13 +R 3 Wall Insulation | 0 | 1 | |
R-13 cavity Wall insulation + R-0 | -1 | 0 | |
R-13 Wall Insulation + high reflectance walls4 | 0 | 1 | |
R-13 wall insulation+ 90% high efficacy lighting and Energy Star Appliances5 | 1 | 2 | |
R-13 Wall Insulation + exterior shading wpf=0.3 6 | 0 | 1 | |
R-30 Roof/ceiling Insulation | 0 | 1 | |
R-19 Roof/ceiling Insulation | -1 | 0 | |
R-19 + Cool roof membrane1 or Radiant Barrier 3 | 0 | 1 | |
R-19 Roof/ceiling Insulation + Attic Venting 2 | 0 | 1 | |
Ductless Air Conditioner 7 | 1 | 1 | |
1.071 X Federal Minimum SEER for Air Conditioner | 1 | 1 | |
1.142 X Federal Minimum SEER for Air Conditioner | 2 | 2 | |
No air conditioning installed | Not Applicable | 2 | |
House floor areas = 1,000 ft 2 | 1 | 1 | |
House floor areas = 2,500 ft2 | -1 | -1 | |
Energy Star Fans8 | 1 | 1 | |
Install 1 kW or greater of solar electric | 1 | 1 | |
Mass Walls | |||
R- 3/4 Wall Insulation | 0 | 1 | |
R-0 Wall Insulation | -1 | 0 | |
R-0 Wall Insulation + high reflectance walls4 | 0 | 1 | |
R-0 Wall Insulation + 90% high efficacy lighting and Energy Star Appliances5 | 1 | 2 | |
R-0 Wall Insulation + exterior shading WPF = 0.36 | 0 | 1 | |
R-19 Roof/ceiling Insulation | -1 | 0 | |
R-19 Roof/ceiling Insulation + Cool roof membrane1 or Radiant Barrier3 | 0 | 1 | |
R-19 Roof Insulation + Attic Venting | 0 | 1 | |
R-30 Roof Insulation | 0 | 1 | |
Ductless Air Conditioner7 | 1 | 1 | |
1.071 X Federal Minimum SEER for Air Conditioner | 1 | 1 | |
1.142 X Federal Minimum SEER for Air Conditioner | 2 | 2 | |
No air conditioning installed | Not Applicable | 2 | |
House floor area = 1,000 ft2 | 1 | 1 | |
House floor area = 2,500 ft2 | -1 | -1 | |
Energy Star Fans8 | 1 | 1 | |
Install 1 kW or greater of solar electric | 1 | 1 |