Section 12-240-5 - Raised characters on hoistway entrances

All elevator hoistway entrances shall have raised floor designations provided on both jambs. The centerline of the characters shall be sixty (60) inches (1525 millimeters) from the floor. Such characters shall two (2) inches or fifty (50) millimeters high and shall comply with ANSI A117.1-1986 Rule 1.30. Permanently applied plates are acceptable if they are permanently fixed to the jambs as shown in Figure 240-1, titled, "Hoistway and Elevator Entrances", dated December 6, 1990, which is made a part of this chapter, and located at the end of this chapter.