Haw. Code R. § 11-45-113

Current through November, 2024
Section 11-45-113 - Specific requirements for radiographic personnel performing industrial radiography
(a) At a jobsite, the following shall be supplied by the licensee:
(1) At least one operable, calibrated survey instrument;
(2) A current whole body personnel monitor (TLD or film badge) for each individual;
(3) An operable, calibrated pocket dosimeter with a range of zero to two hundred milliroentgens (5.16 x 10-5 coulombs per kilogram) for each worker; and
(4) The appropriate barrier ropes and signs.
(b) Industrial radiographic operations shall not be performed if any of the items in subsection (a) are not available at the jobsite or are inoperable.
(c) Each licensee shall provide a minimum of two radiographic personnel when x-ray systems are used at temporary jobsites. If one of the personnel is a radiographer trainee, the other shall be a radiographer instructor.
(d) No individual other than a radiographer or a radiographer trainee who is under the personal supervision of a radiographer instructor shall manipulate controls or operate equipment used in industrial radiographic operations.
(e) No individual shall act as a radiographer instructor unless such individual:
(1) Has met the requirements of subchapter 5;
(2) Has one year of documented experience as a radiographer; and
(3) Has been named as a radiographer instructor on the license issued by the department.
(f) During an inspection by the department, the department inspector may terminate an operation if any of the items in subsection (a) are not available and operable or if the required number of radiographic personnel are not present. Operations shall not be resumed until such conditions are met.

Haw. Code R. § 11-45-113

[Eff 11/12/99] (Auth: HRS §§ 321-10, 321-11, 321-71) (Imp: HRS §§ 321-1, 321-11(21), 321-71)