Haw. Code R. § 11-45-43

Current through November, 2024
Section 11-45-43 - Determination of internal exposure
(a) For purposes of assessing dose used to determine compliance with occupational dose equivalent limits, the licensee shall, when required under section 11-45-54, take suitable and timely measurements of:
(1) Concentrations of radioactive materials in air in work areas; or
(2) Quantities of radionuclides in the body; or
(3) Quantities of radionuclides excreted from the body; or
(4) Combinations of these measurements.
(b) Unless respiratory protective equipment is used, as provided in section 11-45-60, or the assessment of intake is based on bioassays, the licensee shall assume that an individual inhales radioactive material at the airborne concentration in which the individual is present.
(c) When specific information on the physical and biochemical properties of the radionuclides taken into the body or the behavior or the material in an individual is known, the licensee may:
(1) Use that information to calculate the committed effective dose equivalent, and, if used, the licensee shall document that information in the individual's record; and
(2) Upon prior approval of the department, adjust the DAC or ALI values to reflect the actual physical and chemical characteristics of airborne radioactive material, for example, aerosol size distribution or density; and
(3) Separately assess the contribution of fractional intakes of Class D, W, or Y compounds of a given radionuclide to the committed effective dose equivalent. See Appendix B.
(d) If the licensee chooses to assess intakes of Class Y material using the measurements given in subsection (a)(2) or (a)(3), the licensee may delay the recording and reporting of the assessments for periods up to seven months, unless otherwise required by sections 11-45-89 and 11-45-90. This delay licenses the licensee to make additional measurements basic to the assessments.
(e) If the identity and concentration of each radionuclide in a mixture are known, the fraction of the DAC applicable to the mixture for use in calculating DAC-hours shall be either:
(1) The sum of the ratios of the concentration to the appropriate DAC value, that is, D, W, or Y, from Appendix B for each radionuclide in the mixture; or
(2) The ratio of the total concentration for all radionuclides in the mixture to the most restrictive DAC value for any radionuclide in the mixture.
(f) If the identity of each radionuclide in a mixture is known, but the concentration of one or more of the radionuclides in the mixture is not known, the DAC for the mixture shall be the most restrictive DAC of any radionuclide in the mixture.
(g) When a mixture of radionuclides in air exists, a licensee may disregard certain radionuclides in the mixture if:
(1) The licensee uses the total activity of the mixture in demonstrating compliance with the dose limits in section 11-45-40 and in complying with the monitoring requirements in section 11-45-54(b), and
(2) The concentration of any radionuclide disregarded is less than ten percent of its DAC, and
(3) The sum of these percentages for all of the radionuclides disregarded in the mixture does not exceed thirty percent.
(h) When determining the committed effective dose equivalent, the following information may be considered:
(1) In order to calculate the committed effective dose equivalent, the licensee may assume that the inhalation of one ALI, or an exposure of two thousand DAC-hours, results in a committed effective dose equivalent of five rems (0.05 sievert) for radionuclides that have their ALIs or DACs based on the committed effective dose equivalent.
(2) For an ALI and the associated DAC determined by the nonstochastic organ dose limit of fifty rems (0.50 sievert), the intake of radionuclides that would result in a committed effective dose equivalent of five rems (0.05 sievert), that is, the stochastic ALI, is listed in parentheses in Table I of Appendix B. The licensee may, as a simplifying assumption, use the stochastic ALIs to determine committed effective dose equivalent. However, if the licensee uses the stochastic ALIs, the licensee shall also demonstrate that the limit in section 11-45-40(a)(1)(B) is met.
(i) Appendix B to Part D of the Conference of Radiation Control Program Directors, Inc. Suggested State Regulations for Control of Radiation, Volume I, December 1995 Edition, entitled, "Annual Limits on Intake (ALI) and Derived Air Concentrations (DAC) of Radionuclides for Occupational Exposure; Effluent Concentrations; Concentrations for Release to Sanitary Sewerage", is made a part of this section and is available from the department.

Haw. Code R. § 11-45-43

[Eff 11/12/99] (Auth: HRS §§ 321-10, 321-11, 321-71) (Imp: HRS §§ 321-1, 321-11(21), 321-71)