Haw. Code R. § 11-266-108

Current through November, 2024
Section 11-266-108 - Small quantity on-site burner exemption
(a) Exempt quantities. Owners and operators of facilities that burn hazardous waste in an on-site boiler or industrial furnace are exempt from the requirements of this subchapter provided that:
(1) The quantity of hazardous waste burned in a device for a calendar month does not exceed the limits provided in the following table based on the terrain-adjusted effective stack height as defined in paragraph 11-266-106(b) (3):

Exempt Quantities for Small Quantity Burner Exemption

Terrain-adjusted effective stack height of device (meters) Allowable hazardous waste burning rate (gallons/ month) Terrain-adjusted effective stack height of device (meters) Allowable hazardous waste burning rate (Gallons/ month)
0 to 3.9 0 40.0 to 44.9 210
4.0 to 5.9 13 45.0 to 49.9 260
6.0 to 7.9 18 50.0 to 54.9 330
8.0 to 9.9 27 55.0 to 59.9 400
10.0 to 11.9 40 60.0 to 64.9 490
12.0 to 13.9 48 65.0 to 69.9 610
14.0 to 15.9 59 70.0 to 74.9 680
16.0 to 17.9 69 75.0 to 79.9 760
18.0 to 19.9 76 80.0 to 84.9 850
20.0 to 21.9 84 85.0 to 89.9 960
22.0 to 23.9 93 90.0 to 94.9 1,100
24.0 to 25.9 100 95.0 to 99.9 1,200
26.0 to 27.9 110 100.0 to 104.9 1,300
28.0 to 29.9 130 105.0 to 109.9 1,500
30.0 to 34.9 140 110.0 to 114.9 1,700
35.0 to 39.9 170 115.0 or greater 1,900

(2) The maximum hazardous waste firing rate does not exceed at any time one percent of the total fuel requirements for the device (hazardous waste plus other fuel) on a total heat input or mass input basis, whichever results in the lower mass feed rate of hazardous waste.
(3) The hazardous waste has a minimum heating value of five-thousand Btu/lb, as generated; and
(4) The hazardous waste fuel does not contain (and is not derived from) EPA Hazardous Waste Nos. F020, F021, F022, F023, F026, or F027.
(b) Mixing with nonhazardous fuels. If hazardous waste fuel is mixed with a nonhazardous fuel, the quantity of hazardous waste before such mixing is used to comply with subsection (a).
(c) Multiple stacks. If an owner or operator burns hazardous waste in more than one on-site boiler or industrial furnace exempt under this section, the quantity limits provided by paragraph (a)(1) are implemented according to the following equation:

Click Here To View Image

where:

"n" means the number of stacks;

"Actual Quantity Burned" means the waste quantity burned per month in device "i";

"Allowable Quantity Burned" means the maximum allowable exempt quantity for stack "i" from the table in (a)(1) above.

(d) Notification requirements. The owner or operator of facilities qualifying for the small quantity burner exemption under this section must provide a one-time signed, written notice to the department indicating the following:
(1) The combustion unit is operating as a small quantity burner of hazardous waste;
(2) The owner and operator are in compliance with the requirements of this section; and
(3) The maximum quantity of hazardous waste that the facility may burn per month as provided by paragraph (a) (1).
(e) Recordkeeping requirements. The owner or operator must maintain at the facility for at least three years sufficient records documenting compliance with the hazardous waste quantity, firing rate, and heating value limits of this section. At a minimum, these records must indicate the quantity of hazardous waste and other fuel burned in each unit per calendar month, and the heating value of the hazardous waste.

Haw. Code R. § 11-266-108

[Eff 6/18/94; comp] (Auth: HRS §§ 342J-4, 342J-31, 342J-35) (Imp: 40 C.F.R. §266.108 )