Ga. Comp. R. & Regs. 120-3-27-.33

Current through Rules and Regulations filed through October 17, 2024
Rule 120-3-27-.33 - Waste Water Disposal
(1) Overflow water shall be returned to the filter system or discharged to a waste system approved by local authorities. Where perimeter overflow water discharges into a sanitary sewer, a suitable air gap at least 1 1/2 times the discharge diameter shall be provided to create a gravity drip which has no direct mechanical connection into the sewer.
(2) When an air gap is impractical, a relief manhole with a grated cover shall be constructed in the perimeter overflow main waste line, the clear area of which shall be twice the area of the main waste piping. It shall be at a level so that the waste flow in the line will rise in the manhole and overflow at ground level not less than 2 feet (61 cm) below the level of the perimeter overflow lip.

Ga. Comp. R. & Regs. R. 120-3-27-.33

O.C.G.A. Sec. 25-15-59.

Original Rule entitled "Waste Water Disposal"adopted. F. Sep. 4, 2013; eff. Sept. 24, 2013.